DATA LIST
Tech Tips
Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Note
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus:
Body / Air Conditioner / Data List.
Powertrain / Engine and ECT / Data List.
According to the display on the intelligent tester, read the Data List.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Room Temperature Sensor | Room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) |
Actual room temperature for front seat displayed | Open in the circuit: -6.5°C (20.3°F). Short in the circuit: 57.25°C (135.05°F). |
| Ambient Temp Sensor | Ambient temperature sensor / Min.: -23.3°C (-9.94°F) Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | Open in the circuit: -23.3°C (-9.94°F). Short in the circuit: 65.95°C (150.71°F). |
| Adjusted Ambient Temp | Adjusted ambient temperature / Min.: -30.8°C (-23.44°F) Max.: 50.8°C (123.44°F) |
Adjusted ambient temperature displayed | - |
| Evaporator Fin Thermistor | No. 1 cooler thermistor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | Open in the circuit: -29.7°C (-21.46°F). Short in the circuit: 59.55°C (139.19°F). |
| Evaporator Target Temp | Target evaporator temperature / Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Target evaporator temperature displayed | - |
| Solar Sensor (D Side) | Solar sensor / Min.: 0, Max.: 255 | Driver side solar sensor voltage increases as brightness increases | Open in the circuit: 0. Short in the circuit: 255. |
| Solar Sensor (P Side) | Solar sensor / Min.: 0, Max.: 255 | Passenger side solar sensor voltage increases as brightness increases | Open in the circuit: 0. Short in the circuit: 255. |
| Engine Coolant Temp | Engine coolant temperature / Min.: 1.3°C (34.34°F) Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature displayed | - |
| Set Temperature (D Side) | Driver side set temperature / MAX COLD: 0°C (32°F) MAX HOT: 30°C (86°F) |
Driver side set temperature displayed | - |
| Set Temperature (P Side) | Passenger side set temperature / MAX COLD: 0°C (32°F) MAX HOT: 30°C (86°F) |
Passenger side set temperature displayed | - |
| Blower Motor Speed Level | Blower with fan motor sub-assembly speed level / Min.: 0, Max.: 31 | Increases in range between 0 and 31 as blower with fan motor sub-assembly speed increases | - |
| Regulator Pressure Sensor | Refrigerant pressure sensor / Min.: -0.4566 MPa Max.: 3.2943 MPa |
Actual refrigerant pressure displayed | - |
| Regulator Control Current | Compressor assembly with pulley / Min.: 0, Max.: 0.997 | Value changes between 0 A and 0.997 A in accordance with compressor assembly with pulley operation | - |
| Air Mix Servo Targ Pulse (D) | Air mix control servo motor (for driver side) target pulse / Min.: 0, Max.: 255 | for LHD:
for RHD:
|
- |
| Air Mix Servo Actual Pulse (D) | Air mix control servo motor (for driver side) actual pulse / Min.: 0, Max.: 255 | for LHD:
for RHD:
|
- |
| Air Mix Servo Targ Pulse (P) | Air mix control servo motor (for front passenger side) target pulse / Min.: 0, Max.: 255 | for LHD:
for RHD:
|
- |
| Air Mix Servo Actual Pulse (P) | Air mix control servo motor (for front passenger side) actual pulse / Min.: 0, Max.: 255 | for LHD:
for RHD:
|
- |
| Air Outlet Servo Pulse (D) | Air outlet control servo motor target pulse / Min.: 0, Max.: 255 | 47 (pulse): FACE 37 (pulse): B/L 18 (pulse): FOOT 9 (pulse): F/D 5 (pulse): DEF |
- |
| Air Outlet Servo Actu Pulse (D) | Air outlet control servo motor actual pulse / Min.: 0, Max.: 255 | 47 (pulse): FACE 37 (pulse): B/L 18 (pulse): FOOT 9 (pulse): F/D 5 (pulse): DEF |
- |
| Air Inlet Damper Targ Pulse | Damper servo sub-assembly target pulse / Min.: 0, Max.: 255 | for LHD:
for RHD:
|
- |
| Air Inlet Damper Actual Pulse | Damper servo sub-assembly actual pulse / Min.: 0, Max.: 255 | for LHD:
for RHD:
|
- |
| Shift Set Temperature | Set temperature shift / 2C incr, 1C incr, Normal, 1C decr or 2C decr | Customized value displayed | - |
| Air Inlet Mode | Air inlet mode / Auto or Manual | Customized value displayed | - |
| Compressor Mode | Compressor mode / Auto or Manual | Customized value displayed | - |
| Compressor/DEF Mode | Compressor/DEF mode / Link or Normal | Customized value displayed | - |
| Evaporator Control | Evaporator control / Auto or Manual | Customized value displayed | - |
| Foot/DEF Auto Mode | Foot/Def auto mode / ON or OFF | Customized value displayed | - |
| Foot/DEF Auto Blow Up | Foot/Def auto blower level function / ON or OFF | Customized value displayed | - |
| Number of Trouble Codes | Number of trouble codes / Min.: 0, Max.: 255 | Number of DTCs displayed | - |
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| A/C Signal | A/C signal / ON or OFF | ON: A/C switch on OFF: A/C switch off |
- |
ACTIVE TEST
Tech Tips
Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the intelligent tester to the DLC3.
Turn the ignition switch to ON.
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Active Test.
According to the display on the intelligent tester, perform the Active Test.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower with fan motor sub-assembly | Min.: 0, Max.: 31 | - |
| Defogger Relay (Rear) | Rear window defogger relay operation | ON or OFF | - |
| Heater Active Level* | Heater level | Min.: 0, Max.: 3 | - |
| Air Mix Servo Targ Pulse (D) | Air mix control servo motor (for driver side) pulse | Min.: 0, Max.: 255 | - |
| Air Mix Servo Targ Pulse (P) | Air mix control servo motor (for front passenger side) pulse | Min.: 0, Max.: 255 | - |
| Air Outlet Servo Pulse (D) | Air outlet control servo motor pulse | Min.: 0, Max.: 255 | - |
| Air Inlet Damper Targ Pulse | Damper servo sub-assembly target pulse | Min.: 0, Max.: 255 | - |
*: w/ PTC Heater