LIGHT CONTROL RHEOSTAT INSPECTION


  1. INSPECT LIGHT CONTROL RHEOSTAT


    1. Inspect the light control rheostat.


      1. A01INCOE01
        Text in Illustration
        *a

        Component without harness connected

        (Light Control Rheostat)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        8 (TC) - 5 (E) Switch pushed Below 1 Ω
        Off 10 kΩ or higher

        If the result is not as specified, replace the light control rheostat.

      2. A01IOQUE01
        Text in Illustration
        *a

        Component without harness connected

        (Light Control Rheostat)

        Apply battery voltage to the switch connector and check that the light control rheostat illuminates.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → 7 (ILL+)

        Battery negative (-) → 6 (ILL-)

        Illumination illuminates

        If the result is not as specified, replace the light control rheostat.