COMBINATION METER REMOVAL

Tech Tips


  • Use the same procedure for RHD and LHD vehicles.

  • The procedure listed below is for LHD vehicles.


  1. PRECAUTION

    Note

    After turning the ignition switch off, waiting time may be required before disconnecting the cable from the battery terminal. Therefore, make sure to read the disconnecting the cable from the battery terminal notice before proceeding with work Click here.

  2. DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL

    CAUTION:

    Wait at least 90 seconds after disconnecting the cable from the negative (-) battery terminal to disable the SRS system.

    Note

    When disconnecting the cable some systems need to be initialized after the cable is reconnected Click here.

  3. REMOVE INSTRUMENT PANEL FINISH PANEL END LH


    1. for Automatic Air Conditioning System:


      1. A01IQDGE01
        Text in Illustration
        *1 Protective Tape

        Put protective tape around the instrument panel finish panel end LH.

      2. Using a moulding remover A, detach the 3 clips and 2 guides, and remove the instrument panel finish panel end LH.

    2. for Manual Air Conditioning System:


      1. A01ITLUE01
        Text in Illustration
        *1 Protective Tape

        Put protective tape around the instrument panel finish panel end LH.

      2. Using a moulding remover A, detach the 3 clips and guide, and remove the instrument panel finish panel end LH.

  4. REMOVE INSTRUMENT PANEL FINISH PANEL END RH

    A01IU46E01
    Text in Illustration
    *1 Protective Tape

    1. for Automatic Air Conditioning System:


      1. Put protective tape around the instrument panel finish panel end RH.

      2. Using a moulding remover A, detach the 3 clips, claw and 2 guides, and remove the instrument panel finish panel end RH.

    2. A01IQX3E01
      Text in Illustration
      *1 Protective Tape

      for Manual Air Conditioning System:


      1. Put protective tape around the instrument panel finish panel end RH.

      2. Using a moulding remover A, detach the 3 clips, claw and guide, and remove the instrument panel finish panel end.

  5. REMOVE CENTER INSTRUMENT PANEL REGISTER ASSEMBLY

    A01IQZA

    1. Detach the 8 claws and 4 guides.

    2. Disconnect the connector and remove the center instrument panel register.

  6. REMOVE INSTRUMENT CLUSTER FINISH PANEL ASSEMBLY

    A01ISRP

    1. Detach the 4 claws and 11 guides, and remove the instrument cluster finish panel.

  7. REMOVE COMBINATION METER ASSEMBLY


    1. A01INRI

      Remove the 2 screws.

    2. Detach the clip.

    3. A01INN0

      Detach the clamp.

    4. Disconnect the connector and remove the combination meter.