STOP LIGHT CONTROL RELAY (for RHD) INSTALLATION


  1. INSTALL STOP LIGHT CONTROL RELAY ASSEMBLY


    1. A01IU4F

      Attach the clip to install the relay.

    2. Connect the connector.

  2. INSTALL GLOVE COMPARTMENT DOOR ASSEMBLY

    A01IRG9

    1. Attach the 2 hinges to install the glove compartment door.

    2. A01ISP7E01

      Attach the glove compartment door stopper to the glove compartment door as shown in the illustration.

    3. While pushing in the sides of the glove compartment door as indicated by the arrows in the illustration, close the glove compartment door to engage the 2 stoppers.

      Text in Illustration
      *1 Stopper