DESCRIPTION
According to current control by the ECM, the shift solenoid valve SLS controls secondary pulley pressure and belt clamping pressure in accordance with the input shaft torque.
| *1 | Spool Valve | *2 | Sleeve |
| *3 | Solenoid Coil | - | - |
| *a | Hydraulic Pressure | *b | Current Flow to Solenoid |
| DTC Code | DTC Detection Condition
|
Trouble Area |
|---|---|---|
| P282B |
|
|
MONITOR DESCRIPTION
This DTC indicates an open or short circuit in the shift solenoid valve SLS circuit. If there is an open or short circuit in the shift solenoid valve SLS circuit, the ECM detects the problem, illuminates the MIL and stores this DTC.
WIRING DIAGRAM
INSPECTION PROCEDURE
Note
Perform initialization when parts related to the continuously variable transaxle are replaced Click here.
Check that no DTCs are stored after performing initialization Click here.
PROCEDURE
INSPECT TRANSMISSION WIRE (SHIFT SOLENOID VALVE SLS)
| *a | Component without harness connected (Transmission Wire) |
Disconnect the transmission wire connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)
| *a | Front view of wire harness connector (to ECM) |
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR (TRANSMISSION WIRE - ECM) |
| OK |
|
REPLACE ECM
Replace the ECM Click here.
| NEXT |
|
PERFORM INITIALIZATION Click here
REPLACE CONTINUOUSLY VARIABLE TRANSAXLE ASSEMBLY
Replace the continuously variable transaxle assembly Click here.
| NEXT |
|
PERFORM INITIALIZATION Click here