AUTOMATIC TRANSAXLE SYSTEM Transmission Control Switch Circuit

DESCRIPTION

After moving the shift lever to M, it is possible to switch the shift range between "1" (M1 range) and "6" (M6 range) using the transmission control switch.

Moving the shift lever to "+" once raises the shift range by one, and moving the shift lever to "-" once lowers the shift range by one.

WIRING DIAGRAM

A01IMYDE04

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT TRANSMISSION CONTROL SWITCH


    1. A01IOX6E04
      Text in Illustration
      *a

      Component without harness connected

      (Transmission Control Switch)

      Disconnect the transmission control switch connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      6 (IG) - 13 (S) Shift lever in M, "+" or "-" Below 1 Ω
      5 (SFTU) - 11 (E) Shift lever held in "+" (Up-shift) Below 1 Ω
      4 (SFTD) - 11 (E) Shift lever held in "-" (Down-shift) Below 1 Ω
      6 (IG) - 13 (S) Shift lever not in M, "+" or "-" 10 kΩ or higher
      5 (SFTU) - 11 (E) Shift lever in M 10 kΩ or higher
      4 (SFTD) - 11 (E) Shift lever in M 10 kΩ or higher

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL SWITCH - BATTERY AND BODY GROUND)


    1. A01IP9XE06
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Transmission Control Switch)

      Disconnect the transmission control switch connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      H48-6 (IG) - Body ground Ignition switch ON 11 to 14 V
      H48-6 (IG) - Body ground Ignition switch off Below 1 V
    3. Turn the ignition switch off.

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      H48-11 (E) - Body ground Always Below 1 Ω

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (TRANSMISSION CONTROL SWITCH - ECM)


    1. A01IN4TE21
      Text in Illustration
      *a

      Front view of wire harness connector

      (to ECM)

      Disconnect the ECM connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      A51-9 (S) - Body ground
      • Ignition switch ON

      • Shift lever in M, "+" or "-"

      11 to 14 V
      A51-9 (S) - Body ground
      • Ignition switch ON

      • Shift lever not in M, "+" or "-"

      Below 1 V
    3. Turn the ignition switch off.

    4. Disconnect the spiral cable sub-assembly connector.

    5. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A51-19 (SFTU) - Body ground Shift lever held in "+" (Up-shift) Below 1 Ω
      A51-28 (SFTD) - Body ground Shift lever held in "-" (Down-shift) Below 1 Ω
      A51-19 (SFTU) - Body ground Shift lever in M 10 kΩ or higher
      A51-28 (SFTD) - Body ground Shift lever in M 10 kΩ or higher

    NG
    OK