IGNITION SWITCH INSPECTION


  1. INSPECT IGNITION SWITCH ASSEMBLY


    1. A01ITX0E19
      Text in Illustration
      *1

      Component without harness connected

      (Ignition Switch)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      - LOCK 10 kΩ or higher
      2 (AM1) - 3 (ACC) ACC Below 1 Ω

      2 (AM1) - 3 (ACC)

      2 (AM1) - 4 (IG1)

      6 (IG2) - 7 (AM2)

      ON Below 1 Ω

      1 (ST1) - 2 (AM1)

      1 (ST1) - 4 (IG1)

      6 (IG2) - 7 (AM2)

      6 (IG2) - 8 (ST2)

      START Below 1 Ω

      If the result is not as specified, replace the ignition switch assembly.