Click here

VACUUM REGULATING VALVE INSPECTION

Click here
Click here Click here
  1. Click here

    INSPECT VACUUM REGULATING VALVE ASSEMBLY


    1. A01ISDGE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 11.1 to 12.5 Ω
      Table 1. Text in Illustration
      *1

      Component without harness connected

      (Vacuum Regulating Valve)

      If the result is not as specified, replace the vacuum regulating valve assembly.

    2. Inspect vacuum regulating valve operation.


      1. A01ISU2E01

        Check that air flows from port E to G.

      2. A01IODXE01

        Apply battery voltage to the terminals as shown in the illustration.

      3. Check that air flows from port E to the filter.

        If the result is not as specified, replace the vacuum regulating valve assembly.