DESCRIPTION
The injector driver drives the injectors at high speeds with a high-voltage DC/DC converter. The ECM constantly monitors the injector driver and stops the engine if an abnormal condition is detected.
INSPECTION PROCEDURE
After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).
Inspect the fuses of circuits related to this system before performing the following inspection procedure.
PROCEDURE
CHECK EDU (POWER SOURCE)
Disconnect the injector driver (EDU) connectors.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| *1 | Front view of wire harness connector (to Injector Driver (EDU)) |
INSPECT INTEGRATION NO.1 RELAY (EDU RELAY)
Inspect the integration relay (EDU relay) (Click here).
CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - EDU)
Remove the integration relay from the engine room No. 1 relay block.
Disconnect the EDU connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | ||||||
|---|---|---|---|---|---|---|
|
| *1 | Front view of wire harness connector (to EDU) |
| *2 | Engine Room No. 1 Relay Block |
| *3 | Front view of wire harness connector (to Integration Relay) |
Reconnect the EDU connector.
Reinstall the integration relay.
CHECK HARNESS AND CONNECTOR (ENGINE ROOM NO. 1 RELAY BLOCK)
Remove the integration relay from the engine room No. 1 relay block.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | ||||||
|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | ||||||
|---|---|---|---|---|---|---|
|
| *1 | Engine Room No. 1 Relay Block |
| *2 | Front view of wire harness connector (to Integration Relay) |
Reinstall the integration relay.
CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - ECM)
Remove the integration relay from the engine room No. 1 relay block.
Disconnect the ECM connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | ||||||
|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | ||||||
|---|---|---|---|---|---|---|
|
| *1 | Front view of wire harness connector (to ECM) |
| *2 | Engine Room No. 1 Relay Block |
| *3 | Front view of wire harness connector (to Integration Relay) |
Reconnect the ECM connector.
Reinstall the integration relay.
REPLACE EDUClick here
REPLACE INTEGRATION NO.1 RELAY
REPAIR OR REPLACE HARNESS OR CONNECTOR
REPAIR OR REPLACE HARNESS OR CONNECTOR
REPAIR OR REPLACE HARNESS OR CONNECTOR
REPLACE ECMClick here