Click here

ECD SYSTEM Injector Circuit

Click here
Click here Click here
DTC Code DTC Name
  Injector Circuit
Click here

DESCRIPTION

The injector driver drives the injectors at high speeds with a high-voltage DC/DC converter. The ECM constantly monitors the injector driver and stops the engine if an abnormal condition is detected.

Click here

WIRING DIAGRAM

Refer to DTC P062D (Click here).

Click here

INSPECTION PROCEDURE

Note:
  • After replacing the ECM, the new ECM needs registration (Click here) and initialization (Click here).

  • Inspect the fuses of circuits related to this system before performing the following inspection procedure.

Click here

PROCEDURE


  1. Click here

    CHECK EDU (POWER SOURCE)


    1. A01IRVUE06

      Disconnect the injector driver (EDU) connectors.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      C59-2 (+B) - C59-4 (GND) Ignition switch ON 11 to 14 V
      Table 1. Text in Illustration
      *1

      Front view of wire harness connector

      (to Injector Driver (EDU))


  2. Click here

    INSPECT INTEGRATION NO.1 RELAY (EDU RELAY)


    1. Inspect the integration relay (EDU relay) (Click here).


  3. Click here

    CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - EDU)


    1. Remove the integration relay from the engine room No. 1 relay block.

    2. Disconnect the EDU connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      C59-2 (+B) - 1B-8 Always Below 1 Ω
      C59-4 (GND) - Body ground Always Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      C59-2 (+B) or 1B-8 - Body ground Always 10 kΩ or higher
      Table 2. Text in Illustration
      *1

      Front view of wire harness connector

      (to EDU)

      *2 Engine Room No. 1 Relay Block
      *3

      Front view of wire harness connector

      (to Integration Relay)

    4. Reconnect the EDU connector.

    5. Reinstall the integration relay.


  4. Click here

    CHECK HARNESS AND CONNECTOR (ENGINE ROOM NO. 1 RELAY BLOCK)


    1. Remove the integration relay from the engine room No. 1 relay block.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      1B-4 - 1B-6 Always Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      1B-4 or 1B-6 - Body ground Always 10 kΩ or higher
      Table 3. Text in Illustration
      *1 Engine Room No. 1 Relay Block
      *2

      Front view of wire harness connector

      (to Integration Relay)

    3. Reinstall the integration relay.


  5. Click here

    CHECK HARNESS AND CONNECTOR (INTEGRATION RELAY - ECM)


    1. Remove the integration relay from the engine room No. 1 relay block.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      A51-44 (IREL) - 1B-7 Always Below 1 Ω
      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      A51-44 (IREL) or 1B-7 - Body ground Always 10 kΩ or higher
      Table 4. Text in Illustration
      *1

      Front view of wire harness connector

      (to ECM)

      *2 Engine Room No. 1 Relay Block
      *3

      Front view of wire harness connector

      (to Integration Relay)

    4. Reconnect the ECM connector.

    5. Reinstall the integration relay.


  6. Click here

    REPLACE EDUClick here

  7. Click here

    REPLACE INTEGRATION NO.1 RELAY

  8. Click here

    REPAIR OR REPLACE HARNESS OR CONNECTOR

  9. Click here

    REPAIR OR REPLACE HARNESS OR CONNECTOR

  10. Click here

    REPAIR OR REPLACE HARNESS OR CONNECTOR

  11. Click here

    REPLACE ECMClick here