ECM INSTALLATION


  1. INSTALL ECM


    1. A01IRFA

      Install the 2 brackets to the ECM with the 4 screws.

      Torque:
      3.0 N*m  { 31 kgf*cm, 27 in.*lbf }
    2. A01IRFL

      Install the ECM with bracket with the 2 bolts.

      Torque:
      8.0 N*m  { 82 kgf*cm, 71 in.*lbf }
    3. A01IPY2

      Connect the 2 ECM connectors and lower the 2 levers.

      Note


      • When connecting the connector, make sure that dirt, water or other foreign matter is not stuck between the connector and ECM.

      • Make sure that the 2 levers are securely lowered.

  2. INSTALL NO. 2 AIR CLEANER INLET


    1. A01IU27

      Install the No. 2 air cleaner inlet with the bolt.

      Torque:
      7.0 N*m  { 71 kgf*cm, 62 in.*lbf }
  3. INSTALL NO. 1 AIR CLEANER INLET


    1. A01IRC4

      Attach the 2 claws to install the No. 1 air cleaner inlet.

    2. Install the clip.

  4. INSTALL AIR CLEANER CASE SUB-ASSEMBLY


    1. Install the air cleaner case with the 3 bolts.

      Torque:
      7.0 N*m  { 71 kgf*cm, 62 in.*lbf }
  5. INSTALL AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY

  6. INSTALL AIR CLEANER CAP SUB-ASSEMBLY


    1. Connect the air cleaner hose assembly to the turbocharger sub-assembly, and slide the clamp secure it.

    2. A01INV0E02
      Text in Illustration
      *a Upper

      Attach the 4 clamps to install the air cleaner cap sub-assembly.

    3. Connect the PCV hose to the cylinder head cover sub-assembly, and slide the clamp secure it.

    4. Attach the clamp and connect the mass air flow meter connector.

  7. INSTALL RADIATOR SUPPORT OPENING COVER


    1. Attach the 4 hooks to install the radiator support opening cover.

    2. Install the 3 clips.

  8. INSTALL NO. 1 ENGINE COVER


    1. A01INMI

      Attach the 4 clips to install the No. 1 engine cover.

  9. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note

    When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  10. PERFORM REGISTRATION


  11. PERFORM INITIALIZATION


  12. PERFORM THROTTLE VALVE FULLY CLOSED POSITION LEARNING

    Tech Tips

    Be sure to turn off the ignition switch before performing this inspection.


    1. Turn the ignition switch to ON.

    2. Turn the ignition switch off and wait 10 seconds.

      Tech Tips

      The fully closed position of the diesel throttle valve is learned when the ignition switch is turned off.