Click here

2AD-FHV BATTERY / CHARGING SERVICE DATA

Click here
Click here
Table 1. for 100A Type:
Generator brush holder assembly Brush length Standard exposed length 9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum exposed length 4.5 mm (0.177 in.)
Generator rotor assembly resistance Slip ring - Slip ring Standard resistance 1.8 to 2.2 Ω at 20°C (68°F)
Slip ring - Rotor core Standard resistance 10 MΩ or higher
Diameter of the slip rings Standard diameter 14.2 to 14.8 mm (0.559 to 0.583 in.)
Minimum diameter 14.0 mm (0.551 in.)
Table 2. for 130A Type:
Generator brush holder assembly Brush length Standard exposed length 9.5 to 11.5 mm (0.374 to 0.453 in.)
Minimum exposed length 4.5 mm (0.177 in.)
Generator rotor assembly resistance Slip ring - Slip ring Standard resistance 2.3 to 2.7 Ω at 20°C (68°F)
Slip ring - Rotor Standard resistance 10 kΩ or higher
Diameter of the slip rings Standard diameter 14.2 to 14.4 mm (0.559 to 0.567 in.)
Minimum diameter 14.0 mm (0.551 in.)