MANIFOLD ABSOLUTE PRESSURE SENSOR INSTALLATION


  1. INSTALL VACUUM SENSOR ASSEMBLY


    1. A01IPRJ

      Connect the No. 1 air hose to the vacuum sensor.

    2. Install the vacuum sensor with the bolt.

      Torque:
      10 N*m  { 102 kgf*cm, 7 ft.*lbf }
    3. Connect the vacuum sensor connector.

  2. INSTALL NO. 2 CYLINDER HEAD COVER


    1. A01IRS7

      Attach the 4 clips to install the cover.

      Note


      • Be sure to attach the clips securely.

      • Do not apply excessive force or hit the cover to attach the clips. This may cause the cover to break.