METER / GAUGE SYSTEM Odo/Trip Switch Malfunction

Click here
Click here Click here
DTC Code DTC Name
  Odo/Trip Switch Malfunction
Click here

DESCRIPTION

The meter CPU receives ODO/TRIP change switch signal from the light control rheostat via the direct line.

Tip:

The whole light control rheostat should be replaced if the ODO/TRIP switch is malfunctioning.

Click here

WIRING DIAGRAM

Click here

INSPECTION PROCEDURE

Click here

PROCEDURE


  1. Click here

    READ VALUE USING INTELLIGENT TESTER (ODO/TRIP CHANGE SW)


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the tester on.

    4. Enter the following menus: Body Electrical / Combination Meter / Data List.

    5. Check the values by referring to the table below.

      Table 1. Combination Meter
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      ODO/TRIP Change SW ODO/TRIP change switch/OFF or ON OFF: ODO/TRIP change switch released -
      ON: ODO/TRIP change switch pressed
      OK
      The value displayed on the intelligent tester changes with the actual ODO/TRIP change switch operation.

  2. Click here

    INSPECT LIGHT CONTROL RHEOSTAT


    1. for RHD


      1. A01NIMBE01

        Remove the light control rheostat.

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        2 (A/B) - 5 (E) ODO/TRIP change switch pressed Below 1 Ω
        2 (A/B) - 5 (E) ODO/TRIP change switch not pressed 10 kΩ or higher
        Table 2. Text in Illustration
        *1

        Component without harness connected

        (Light Control Rheostat)

    2. for LHD


      1. A01NJUWE01

        Remove the light control rheostat.

      2. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        2 (A/B) - 5 (E) ODO/TRIP change switch pressed Below 1 Ω
        2 (A/B) - 5 (E) ODO/TRIP change switch not pressed 10 kΩ or higher
        Table 3. Text in Illustration
        *1

        Component without harness connected

        (Light Control Rheostat)


  3. Click here

    CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - LIGHT CONTROL RHEOSTAT)


    1. A01NK30E01

      Disconnect the F16 connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F16-9 (A/B) - F6-2 (A/B) Always Below 1 Ω
      F16-9 (A/B) - Body ground Always 10 kΩ or higher
      Table 4. Text in Illustration
      *1

      Front view of wire harness connector

      (to Combination Meter Assembly)

      *2

      Front view of wire harness connector

      (to Light Control Rheostat)


  4. Click here

    REPLACE COMBINATION METER ASSEMBLYClick here

  5. Click here

    REPLACE LIGHT CONTROL RHEOSTATClick here

  6. Click here

    REPAIR OR REPLACE HARNESS OR CONNECTOR