PRECAUTION
Note
After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) battery terminal notice before proceeding with work Click here.
DISCONNECT CABLE FROM NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
REMOVE FRONT CENTER FLOOR COVER
| *1 | Bolt |
| *2 | Screw |
Remove the 7 bolts and 2 screws.
Disconnect the 3 clips and remove the front center floor cover.
REMOVE CHARCOAL CANISTER ASSEMBLY
| *1 | Retainer |
Push the retainer shown in the illustration and disconnect the vent line tube.
Disconnect the purge line hose.
Disconnect the air inlet line hose.
Remove the 2 bolts and clip.
Disconnect the 3 clamps.
Remove the 2 bolts and charcoal canister assembly.