INSTALL HYBRID BATTERY JUNCTION BLOCK ASSEMBLY
Be sure to wear insulated gloves and protective goggles.
Install the 2 bolts and EV battery fuse.
| 3.5 N*m | 36 kgf*cm | 31 in.*lbf |
Be sure to use a torque wrench to tighten the nuts.
Install the hybrid battery junction block assembly with the 3 nuts.
| 7.5 N*m | 76 kgf*cm | 66 in.*lbf |
Connect the 2 connectors to the hybrid battery junction block assembly.
Make sure that the connectors are fully engaged.
Connect the connector and 2 main battery cable connectors to the hybrid battery junction block assembly.
Install the No. 3 wire frame to the hybrid battery junction block assembly with the 2 nuts.
| *1 | Red Tape |
| 9.0 N*m | 92 kgf*cm | 80 in.*lbf |
Make sure that the ends of the No. 3 wire frame do not cross over each other.
Be sure to connect the No. 3 wire frame to each correct terminal as shown in the illustration.
CHECK HIGH VOLTAGE CABLE CONNECTION
Wear insulated gloves and protective goggles.
Check that each wire harness is being installed securely.
| *1 | Red Tape | *2 | No. 3 Wire Frame |
| *3 | Plastic Cover | - | - |
Make sure that the end of the No. 3 wire frame do not cross each other.
Be sure to connect the No. 3 wire frame to each correct terminal as shown in the illustration.
The connectors should be connected securely.
The nuts should be fastened securely.
Make sure that the 4 plastic covers are engaged securely.
INSTALL BATTERY COVER SUB-ASSEMBLY
INSTALL SERVICE PLUG GRIP
Wear insulated gloves.
Before connecting the service plug, check that no parts and tools remain and that the high voltage terminals and connectors are connected securely.
Wear insulated gloves and insert the service plug grip in the order shown in the illustration.
Tilt the service plug grip 90° and slide it down until a click sound is heard.
INSTALL BATTERY SERVICE HOLE COVER
Engage the 2 clips, 2 guides and install the battery service hole cover.
Make sure that the battery service hole cover is installed securely.
CONNECT CABLE TO NEGATIVE AUXILIARY BATTERY TERMINAL
PERFORM INITIALIZATION
Some systems need initialization after reconnecting the cable to the negative auxiliary battery terminal (Click here).