LIGHTING SYSTEM Interior Light Auto Cut Circuit

DESCRIPTION

When battery saving control operates while the interior lights are on, the main body ECU (multiplex network body ECU) opens the DOME relay to turn off the lights.

WIRING DIAGRAM

A019K92E01

INSPECTION PROCEDURE

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. PERFORM ACTIVE TEST USING INTELLIGENT TESTER


    1. Connect the intelligent tester to the DLC3.

    2. Turn the engine switch on (IG).

    3. Turn the intelligent tester on.

    4. Enter the following menus: Body Electrical / Main Body / Active Test.

    5. Check that the relay operates.

      Main Body
      Tester Display Test Part Control Range Diagnostic Note
      Relay for Interior Light Auto Cut Function Light cut relay (DOME relay) ON/OFF

      Any interior light comes on.


      • ON: Light goes off

      • OFF: Light turns on

      OK
      DOME relay operates.

    NG
    OK
  2. INSPECT DOME RELAY


    1. Remove the DOME relay from the No. 1 relay block assembly.

    2. A019JQIE06
      Text in Illustration
      *1

      Component without harness connected

      (DOME relay)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Voltage is not applied between terminals 1 and 2 10 kΩ or higher
      3 - 5 Voltage is applied between terminals 1 and 2 Below 1 Ω

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (DOME RELAY - MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU))


    1. Disconnect the F12 main body ECU (multiplex network body ECU) connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Relay terminal 1 - Body ground Always 10 kΩ or higher

    NG
    OK