INSTALL NO. 1 HEIGHT CONTROL VALVE SUB-ASSEMBLY
Install the No. 1 height control valve sub-assembly with the 2 bolts.
Coat 5 new O-rings with MP grease No. 2.
Install 5 new O-rings and connect the 3 height control tubes onto the No. 1 height control valve sub-assembly.
Tech Tips
For the connecting procedure of the tube (type 3), refer to Precaution of Suspension Control System Click here.
Lock the 3 holders.
Connect the connector and engage the clamp.
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
Note
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.
INSPECT FOR AIR LEAK
Inspect for air leaks Click here.
INSTALL FRONT BUMPER ASSEMBLY
for Standard: Click here
for Sport package: Click here
PERFORM INITIALIZATION
Perform initialization Click here.
Note