AUTOMATIC TRANSAXLE SYSTEM, Diagnostic DTC:P2810

DTC Code DTC Name
P2810 Pressure Control Solenoid "G" Electrical (Shift Solenoid Valve SL4)

DESCRIPTION

Changing from 1st to 6th is performed by the TCM turning shift solenoid valves SL1, SL2, SL3, SL4 and SL on and off. If an open or short circuit occurs in any of the shift solenoid valves, the TCM controls the remaining normal shift solenoid valves to allow the vehicle to be operated Click here.

DTC No.

DTC Detection Condition


  1. Diagnosis Condition

  2. Malfunction Status

  3. Malfunction Time

  4. Other

Trouble Area
P2810
  1. While driving and shifting gears

  2. Open or short in the shift solenoid valve SL4 circuit


    • Output signal duty equals 100%.

      (NOTE: SL4 output signal duty is less than 100% under normal condition.)

  3. 1 second or more

  4. 1 trip detection logic


  • Open or short in shift solenoid valve SL4 circuit

  • Shift solenoid valve SL4

  • TCM

MONITOR DESCRIPTION

The TCM commands gear shifts by turning the shift solenoid valves on or off. When there is an open or short circuit in any shift solenoid valve circuit, the TCM detects the problem, illuminates the MIL and stores the DTC. And the TCM performs the fail-safe function and turns the other normal shift solenoid valves on or off (In case of an open or short circuit, the TCM stops sending current to the circuit.)

Click here.

WIRING DIAGRAM

A019OI6E36

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (SL4)


    1. A019O6VE63
      Text in Illustration
      *1

      Component without harness connected

      (Transmission Wire)

      Remove the TCM from the transaxle.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      22 (SL4+) - 21 (SL4-) 20°C (68°F) 5.0 to 5.6 Ω
      22 (SL4+) - Body ground Always 10 kΩ or higher
      21 (SL4-) - Body ground Always 10 kΩ or higher
      22 (SL4+) - All other terminals except 21 (SL4-) Always 10 kΩ or higher
      21 (SL4-) - All other terminals except 22 (SL4+) Always 10 kΩ or higher
      Result
      Result Proceed to
      OK B
      NG A

    B
    A
  2. INSPECT SHIFT SOLENOID VALVE SL4


    1. A019JXAE22
      Text in Illustration
      *1 Shift Solenoid Valve SL4

      Remove shift solenoid valve SL4.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    3. Connect a battery positive (+) lead with a 21 W bulb to terminal 2 and a negative (-) lead to terminal 1 of the solenoid valve connector. Then check that the valve moves and makes an operating sound.

      OK
      Valve moves and makes an operating sound.

    NG
    OK