INSPECT CHARCOAL CANISTER ASSEMBLY
Visually check the charcoal canister.
Visually check the charcoal canister for cracks or damage.
Tech Tips
If cracks or damage are found, replace the charcoal canister assembly.
Check charcoal canister airflow.
Using a vacuum pump, check that air flows through the canister according to the instructions below.
| Result | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
If the result is not as specified, replace the charcoal canister assembly.
CLEAN CHARCOAL CANISTER ASSEMBLY
| *a | Air |
Clean the filter by blowing 5 kPa (0.1 kgf/cm2, 0.7 psi) of compressed air into port A while holding port B closed.
Note
Make sure to clean the filter using only air.
Do not use gasoline or any other means.
Do not disassemble the charcoal canister assembly.