CRANKSHAFT POSITION SENSOR INSPECTION


  1. INSPECT CRANKSHAFT POSITION SENSOR


    1. A019JPOE04

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Temperature Specified Condition
      Cold 1,630 to 2,740 Ω
      Hot 2,065 to 3,225 Ω

      Tech Tips

      "Cold" and "Hot" mean the temperature of the coils themselves. "Cold" is from -10 to 50°C (14 to 122 °F) and "Hot" is from 50 to 100°C (122 to 212°F).

      If the resistance is not as specified, replace the sensor.