ЭЛЕКТРОДВИГАТЕЛЬ ВЕНТИЛЯТОРА СИСТЕМЫ ОХЛАЖДЕНИЯ ПРОВЕРКА БЕЗ СНЯТИЯ С АВТОМОБИЛЯ


  1. INSPECT COOLING FAN MOTOR


    1. Disconnect the cooling fan motor connector.

    2. Check that the fan rotates smoothly by hand.

    3. A01FSOVE02
      Text in Illustration
      *a

      Component without harness connected

      (Cooling Fan Motor)

      Check that the cooling fan motor operates smoothly when the auxiliary battery is connected to the cooling fan motor connector.

    4. Measure the current while the cooling fan motor is operating.

      Standard Current
      Item Condition Specified Condition
      Cooling fan motor Auxiliary battery voltage applied at 20°C (68°F) 13.0 to 19.0 A

      If the result is not as specified, replace the cooling fan motor.

    5. Connect the cooling fan motor connector.

  2. INSPECT NO. 2 COOLING FAN MOTOR


    1. Disconnect the No. 2 cooling fan motor connector.

    2. Check that the fan rotates smoothly by hand.

    3. A01FSOVE02
      Text in Illustration
      *a

      Component without harness connected

      (No. 2 Cooling Fan Motor)

      Check that the No. 2 cooling fan motor operates smoothly when the auxiliary battery is connected to the No. 2 cooling fan motor connector.

    4. Measure the current while the No. 2 cooling fan motor is operating.

      Standard Current
      Item Condition Specified Condition
      No. 2 Cooling fan motor Auxiliary battery voltage applied at 20°C (68°F) 13.0 to 19.0 A

      If the result is not as specified, replace the No. 2 cooling fan motor.

    5. Connect the No. 2 cooling fan motor connector.