СИСТЕМА УПРАВЛЕНИЯ ГИБРИДНОЙ СИСТЕМОЙ, Diagnostic DTC:P0A94-585

DTC Code DTC Name
P0A94-585 DC / DC Converter Performance

DESCRIPTION

Refer to the description for DTC P0A94-589 Click here.

DTC No. DTC Detection Condition Trouble Area
P0A94-585

Boost converter voltage (VL) sensor performance problem

When not boosting, differences between "VL-Voltage before Boosting" and "Power Resource VB", and "VL-Voltage before Boosting" and "VH-Voltage after Boosting" are large.

(1 trip detection logic)

Inverter with converter assembly
Related Data List
DTC No. Data List
P0A94-585
  • VL-Voltage before Boosting

  • Power Resource VB

  • VH-Voltage after Boosting

  • Boost Ratio

INSPECTION PROCEDURE

Tech Tips

When the accelerator pedal is not depressed with the power switch on (READY) and the shift lever in P, if "VH-Voltage after Boosting" and the "Power Resource VB" is approximately same after repair, the condition is judged as normal.

PROCEDURE


  1. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check for DTCs.

      Result
      Result Proceed to
      P0A94-585 only is output, or DTCs except the ones in the tables below are also output. A
      DTCs shown in Table 1 are output simultaneously. B
      DTCs shown in Table 2 are output simultaneously. C
      Table 1
      DTC No. Relevant Diagnosis
      P0A1A-151, 155, 156, 658, 659 Generator Control Module
      P0A1B-164, 193, 512, 661, 786 Drive Motor "A" Control Module
      P0A1D-148 Hybrid Powertrain Control Module
      P0A78-266, 267 Drive Motor "A" Inverter Performance
      P0A94-589, 590 DC / DC Converter Performance
      P2511-149 ECM/PCM Power Relay Sensor Circuit Intermittent
      P3004-132 High Voltage Power Resource
      P324E-788 MG-ECU Power Relay Intermittent Circuit
      U0110 (all INF codes)*1 Lost Communication with Drive Motor Control Module "A"
      Table 2
      DTC No. Relevant Diagnosis
      P0AFC-123 Hybrid Battery Pack Sensor Module
      P0B3D-123 Hybrid Battery Voltage Sensor "A" Circuit Low
      P0B42-123 Hybrid Battery Voltage Sensor "B" Circuit Low
      P0B47-123 Hybrid Battery Voltage Sensor "C" Circuit Low
      P0B4C-123 Hybrid Battery Voltage Sensor "D" Circuit Low
      P0B51-123 Hybrid Battery Voltage Sensor "E" Circuit Low
      P0B56-123 Hybrid Battery Voltage Sensor "F" Circuit Low
      P0B5B-123 Hybrid Battery Voltage Sensor "G" Circuit Low
      P0B60-123 Hybrid Battery Voltage Sensor "H" Circuit Low
      P0B65-123 Hybrid Battery Voltage Sensor "I" Circuit Low
      P0B6A-123 Hybrid Battery Voltage Sensor "J" Circuit Low
      P0B6F-123 Hybrid Battery Voltage Sensor "K" Circuit Low
      P0B74-123 Hybrid Battery Voltage Sensor "L" Circuit Low
      P0B79-123 Hybrid Battery Voltage Sensor "M" Circuit Low
      P0B7E-123 Hybrid Battery Voltage Sensor "N" Circuit Low
      P0B83-123 Hybrid Battery Voltage Sensor "O" Circuit Low
      P0B88-123 Hybrid Battery Voltage Sensor "P" Circuit Low
      P0B8D-123 Hybrid Battery Voltage Sensor "Q" Circuit Low
      P308A-123 Hybrid Battery Voltage Sensor All Circuits Low

      Tech Tips


      • *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

      • P0A94-585 may be stored due to a malfunction which causes the DTCs in the preceding tables to be stored. In this case, first troubleshoot the output DTCs in the preceding tables. Then, perform a reproduction test to check that no DTCs are output.

    5. Turn the power switch off.


    B
    C
    A