СИСТЕМА УПРАВЛЕНИЯ ГИБРИДНОЙ СИСТЕМОЙ, Diagnostic DTC:P0A7A-122

DTC Code DTC Name
P0A7A-122 Generator Inverter Performance

DESCRIPTION

For a description of the inverter Click here.

DTC No. DTC Detection Condition Trouble Area
P0A7A-122

Generator inverter fail signal detection (overcurrent due to system malfunction)

A malfunction is detected in any of the generator components (generator inverter, generator, MG ECU, etc.).

(1 trip detection logic)


  • Power management control ECU

  • Inverter with converter assembly

  • Hybrid vehicle transmission assembly

  • Generator cable

  • Motor cable

  • Wire harness or connector

  • IGCT NO. 4 fuse

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A1A-200 Click here.

Refer to the wiring diagram for DTC P0AA6-526 Click here.

Refer to the wiring diagram for DTC P324E-788 Click here.

Refer to the wiring diagram for DTC U0110-159 Click here.

INSPECTION PROCEDURE

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

Tech Tips

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.


  1. Turn the power switch on (READY) and wait for 5 seconds or more.

  2. Drive the vehicle for approximately 10 minutes mainly using the engine.

PROCEDURE


  1. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check for DTCs.

      Result
      Result Proceed to
      P0A7A-122 is stored before any of the DTCs in the tables below are stored. A
      Any of the DTCs including pending DTCs in table 1 below are stored before P0A7A-122 is stored. B
      Any of the DTCs including pending DTCs in table 2 below are stored before P0A7A-122 is stored. C
      Table 1
      Relevant DTC
      P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low
      P0ADC-226 Hybrid Battery Positive Contactor Control Circuit High
      P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low
      P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High
      P3004-803 High Voltage Power Resource
      Table 2
      Relevant DTC
      P0A9C-123 Hybrid Battery Temperature Sensor "A" Range / Performance
      P0A9D-123 Hybrid Battery Temperature Sensor "A" Circuit Low
      P0A9E-123 Hybrid Battery Temperature Sensor "A" Circuit High
      P0AC0-123 Hybrid Battery Pack Current Sensor Circuit Range/Performance
      P0AC1-123 Hybrid Battery Pack Current Sensor Circuit Low
      P0AC2-123 Hybrid Battery Pack Current Sensor Circuit High
      P0AC6-123 Hybrid Battery Temperature Sensor "B" Range/Performance
      P0AC7-123 Hybrid Battery Temperature Sensor "B" Circuit Low
      P0AC8-123 Hybrid Battery Temperature Sensor "B" Circuit High
      P0ACB-123 Hybrid Battery Temperature Sensor "C" Range / Performance
      P0ACC-123 Hybrid Battery Temperature Sensor "C" Circuit Low
      P0ACD-123 Hybrid Battery Temperature Sensor "C" Circuit High
      P0AFC-123 Hybrid Battery Pack Sensor Module
      P3011-123, P3012-123, P3013-123, P0314-123, P3015-123, P3016-123, P0317-123, P3018-123, P3019-123, P3020-123, P3021-123, P3022-123, P3023-123, P3024-123, P3025-123, P3026-123 Battery Block # Becomes Weak
      P3065-123 Hybrid Battery Temperature Sensor Range/ Performance Stuck "A"
      P308A-123 Hybrid Battery Voltage Sensor All Circuits Low

      Tech Tips


      • Refer to the freeze frame data to determine the order in which the DTCs were stored.

      • P0A7A-122 may be stored due to a malfunction which also causes DTCs in the preceding tables to be stored. In this case, first troubleshoot the output DTCs in the preceding tables. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.

    5. Turn the power switch off.


    B
    C
    A
  2. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check for DTCs

      Result
      Result Proceed to
      P0A7A-203 is not output. A
      P0A7A-203 is also output. B

      Note


      • If P0A7A-203 is output, troubleshoot it first. After completing the troubleshooting for P0A7A-203, perform troubleshooting for this DTC.

      • Parts repaired or replaced during troubleshooting for P0A7A-203 do not need to be re-inspected in this diagnosis procedure.

    5. Turn the power switch off.


    B
    A
  3. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check for DTCs.

      Tech Tips


      • If P0A7A-203 was not output in step 2 of this diagnosis procedure, check Table 1 below.

      • If P0A7A-203 was output in step 2 of this diagnosis procedure, diagnose that DTC first, then check Table 2 below.

      Result
      Result Proceed to
      P0A7A-122 only is output, or DTCs except the ones in the tables below are also output. A
      Any of the following DTCs including pending DTCs are also output. B
      Table 1
      Relevant DTC
      P0A1A (all INF codes)*1 Generator Control Module
      P0A1B (all INF codes)*1 Drive Motor "A" Control Module
      P0A1D (all INF codes)*1 Hybrid Powertrain Control Module
      P0A3F-243 Drive Motor "A" Position Sensor Circuit
      P0A40-500 Drive Motor "A" Position Sensor Circuit Range/Performance
      P0A41-245 Drive Motor "A" Position Sensor Circuit Low
      P0A4B-253 Generator Position Sensor Circuit
      P0A4C-513 Generator Position Sensor Circuit Range/Performance
      P0A4D-255 Generator Position Sensor Circuit Low
      P0A60 (all INF codes)*1 Drive Motor "A" Phase V Current
      P0A63 (all INF codes)*1 Drive Motor "A" Phase W Current
      P0A72 (all INF codes)*1 Generator Phase V Current
      P0A75 (all INF codes)*1 Generator Phase W Current
      P0A78-266, 267, 279, 287, 306, 503, 504, 505, 506, 586, 806, 807, 808 Drive Motor "A" Inverter Performance
      P0A7A-325, 344, 517, 518, 809, 810, 811 Generator Inverter Performance
      P0A90-509 Drive Motor "A" Performance
      P0A92-521 Hybrid Generator Performance
      P0A94-442, 547, 548, 549, 554, 555, 556, 585, 587, 589, 590 DC/DC Converter Performance
      P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low
      P0ADC-226 Hybrid Battery Positive Contactor Control Circuit High
      P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low
      P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High
      P0C76-523 Hybrid Battery System Discharge Time Too Long
      P3004-803 High Voltage Power Resource
      Table 2
      Relevant DTC
      P0A1A (all INF codes)*1 Generator Control Module
      P0A1B (all INF codes)*1 Drive Motor "A" Control Module
      P0A1D (all INF codes)*1 Hybrid Powertrain Control Module
      P0A3F-243 Drive Motor "A" Position Sensor Circuit
      P0A40-500 Drive Motor "A" Position Sensor Circuit Range/Performance
      P0A41-245 Drive Motor "A" Position Sensor Circuit Low
      P0A4B-253 Generator Position Sensor Circuit
      P0A4C-513 Generator Position Sensor Circuit Range/Performance
      P0A4D-255 Generator Position Sensor Circuit Low
      P0A60 (all INF codes)*1 Drive Motor "A" Phase V Current
      P0A63 (all INF codes)*1 Drive Motor "A" Phase W Current
      P0A72-333 Generator Phase V Current
      P0A75-341 Generator Phase W Current
      P0A78-266, 267, 279, 287, 306, 503, 504, 505, 506, 586, 806, 807, 808 Drive Motor "A" Inverter Performance
      P0A7A-325, 517, 518, 809, 810, 811 Generator Inverter Performance
      P0A90-509 Drive Motor "A" Performance
      P0A94-442, 547, 548, 549, 554, 555, 556, 585, 587, 589, 590 DC/DC Converter Performance
      P0ADB-227 Hybrid Battery Positive Contactor Control Circuit Low
      P0ADC-226 Hybrid Battery Positive Contactor Control Circuit High
      P0ADF-229 Hybrid Battery Negative Contactor Control Circuit Low
      P0AE0-228 Hybrid Battery Negative Contactor Control Circuit High
      P0C76-523 Hybrid Battery System Discharge Time Too Long
      P3004-803 High Voltage Power Resource

      Tech Tips


      • *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

      • P0A7A-122 may be stored due to a malfunction which also causes DTCs in the preceding tables to be stored. In this case, first troubleshoot the output DTCs in the preceding tables. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.

    5. Turn the power switch off.


    B
    A
  4. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Check connection condition of the low voltage connector of the inverter with converter assembly and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter Click here.

      A01FRYME01
      Text in Illustration
      *A for LHD *B for RHD

      Note

      Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

      OK
      - The connector is connected securely.
      - The terminals are not deformed and are connected securely.
      - No water or foreign matter in the connector.
      Result
      Result Proceed to
      OK A
      NG (The connector is not connected securely.) B
      NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C

      Tech Tips

      When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.


    B
    C
    A
  5. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the power switch on (IG).

    5. A01FQOWE17
      Text in Illustration
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-20 (GRF) - Body ground Power switch on (IG) Below 1 V
      A38-9 (GRFG) - Body ground Power switch on (IG) Below 1 V
      A38-18 (GSN) - Body ground Power switch on (IG) Below 1 V
      A38-7 (GSNG) - Body ground Power switch on (IG) Below 1 V
      A38-17 (GCS) - Body ground Power switch on (IG) Below 1 V
      A38-6 (GCSG) - Body ground Power switch on (IG) Below 1 V
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-20 (GRF) - Body ground Power switch on (IG) Below 1 V
      A74-9 (GRFG) - Body ground Power switch on (IG) Below 1 V
      A74-18 (GSN) - Body ground Power switch on (IG) Below 1 V
      A74-7 (GSNG) - Body ground Power switch on (IG) Below 1 V
      A74-17 (GCS) - Body ground Power switch on (IG) Below 1 V
      A74-6 (GCSG) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Turn the power switch off.

    7. Disconnect the cable from the negative (-) auxiliary battery terminal.

    8. Reconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD


    NG
    OK
  6. CHECK GENERATOR RESOLVER

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD

    3. A01FQOWE17
      Text in Illustration
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-20 (GRF) - A38-9 (GRFG) Power switch off 4.2 to 12.5 Ω
      A38-18 (GSN) - A38-7 (GSNG) Power switch off 9.8 to 20.1 Ω
      A38-17 (GCS) - A38-6 (GCSG) Power switch off 9.8 to 20.1 Ω
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-20 (GRF) - A74-9 (GRFG) Power switch off 4.2 to 12.5 Ω
      A74-18 (GSN) - A74-7 (GSNG) Power switch off 9.8 to 20.1 Ω
      A74-17 (GCS) - A74-6 (GCSG) Power switch off 9.8 to 20.1 Ω
      Standard Resistance (Check for Short)
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-20 (GRF) or A38-9 (GRFG) - Body ground and other terminals Power switch off 1 MΩ or higher
      A38-18 (GSN) or A38-7 (GSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
      A38-17 (GCS) or A38-6 (GCSG) - Body ground and other terminals Power switch off 1 MΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-20 (GRF) or A74-9 (GRFG) - Body ground and other terminals Power switch off 1 MΩ or higher
      A74-18 (GSN) or A74-7 (GSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
      A74-17 (GCS) or A74-6 (GCSG) - Body ground and other terminals Power switch off 1 MΩ or higher
    4. Reconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD


    NG
    OK
  7. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the power switch on (IG).

    5. A01FQOWE18
      Text in Illustration
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-40 (MRF) - Body ground Power switch on (IG) Below 1 V
      A38-29 (MRFG) - Body ground Power switch on (IG) Below 1 V
      A38-39 (MSN) - Body ground Power switch on (IG) Below 1 V
      A38-28 (MSNG) - Body ground Power switch on (IG) Below 1 V
      A38-38 (MCS) - Body ground Power switch on (IG) Below 1 V
      A38-27 (MCSG) - Body ground Power switch on (IG) Below 1 V
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-40 (MRF) - Body ground Power switch on (IG) Below 1 V
      A74-29 (MRFG) - Body ground Power switch on (IG) Below 1 V
      A74-39 (MSN) - Body ground Power switch on (IG) Below 1 V
      A74-28 (MSNG) - Body ground Power switch on (IG) Below 1 V
      A74-38 (MCS) - Body ground Power switch on (IG) Below 1 V
      A74-27 (MCSG) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Turn the power switch off.

    7. Disconnect the cable from the negative (-) auxiliary battery terminal.

    8. Reconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD


    NG
    OK
  8. CHECK MOTOR RESOLVER

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD

    3. A01FQOWE18
      Text in Illustration
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-40 (MRF) - A38-29 (MRFG) Power switch off 4.2 to 12.5 Ω
      A38-39 (MSN) - A38-28 (MSNG) Power switch off 9.8 to 20.1 Ω
      A38-38 (MCS) - A38-27 (MCSG) Power switch off 9.8 to 20.1 Ω
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-40 (MRF) - A74-29 (MRFG) Power switch off 4.2 to 12.5 Ω
      A74-39 (MSN) - A74-28 (MSNG) Power switch off 9.8 to 20.1 Ω
      A74-38 (MCS) - A74-27 (MCSG) Power switch off 9.8 to 20.1 Ω
      Standard Resistance (Check for Short)
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-40 (MRF) or A38-29 (MRFG) - Body ground and other terminals Power switch off 1 MΩ or higher
      A38-39 (MSN) or A38-28 (MSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
      A38-38 (MCS) or A38-27 (MCSG) - Body ground and other terminals Power switch off 1 MΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-40 (MRF) or A74-29 (MRFG) - Body ground and other terminals Power switch off 1 MΩ or higher
      A74-39 (MSN) or A74-28 (MSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
      A74-38 (MCS) or A74-27 (MCSG) - Body ground and other terminal Power switch off 1 MΩ or higher
    4. Reconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD


    NG
    OK
  9. CHECK INVERTER WITH CONVERTER ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01FVW4E01
      Text in Illustration
      *A for LHD
      *B for RHD

      for Type A:


      1. Remove the inverter terminal cover from the inverter with converter assembly.

    3. A01FUAXE02
      Text in Illustration
      *A for LHD
      *B for RHD

      for Type B:


      1. Remove the inverter terminal cover from the inverter with converter assembly.

    4. A01FS0JE01
      Text in Illustration
      *A for LHD
      *B for RHD
      *1

      Generator Cable

      (Inverter with Converter Assembly Side)

      Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected

      Specified Condition
      T=8.0 N*m (82 kgf*cm, 71 in.*lbf)

      Note

      Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

    5. Disconnect the generator cable from the inverter with converter assembly.

    6. Check for arc marks at the terminals for the generator cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    7. Connect the generator cable to the inverter with converter assembly.

    8. Install the inverter terminal cover.


    B
    C
    A
  10. CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01FVW4E01
      Text in Illustration
      *A for LHD
      *B for RHD

      for Type A:


      1. Remove the inverter terminal cover from the inverter with converter assembly.

    3. A01FUAXE02
      Text in Illustration
      *A for LHD
      *B for RHD

      for Type B:


      1. Remove the inverter terminal cover from the inverter with converter assembly.

    4. A01FVT0E01
      Text in Illustration
      *A for LHD
      *B for RHD
      *1

      Motor Cable

      (Inverter with Converter Assembly Side)

      Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

      Specified Condition
      T=8.0 N*m (82 kgf*cm, 71 in.*lbf)

      Note

      Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

    5. Disconnect the motor cable from the inverter with converter assembly.

    6. Check for arc marks at the terminals for the motor cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    7. Connect the motor cable to the inverter with converter assembly.

    8. Install the inverter terminal cover.


    B
    C
    A
  11. CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MG1)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01FVW4E01
      Text in Illustration
      *A for LHD
      *B for RHD

      for Type A:


      1. Remove the inverter terminal cover from the inverter with converter assembly.

    3. A01FUAXE02
      Text in Illustration
      *A for LHD
      *B for RHD

      for Type B:


      1. Remove the inverter terminal cover from the inverter with converter assembly.

    4. A01FUG0E01
      Text in Illustration
      *A for LHD
      *B for RHD
      *1 Motor Cable
      *2 Generator Cable

      Disconnect the generator cable and motor cable from the inverter with converter assembly.

    5. A01FSH3E04
      Text in Illustration
      *A for LHD
      *B for RHD
      *1 Shield Ground
      *a

      Generator Cable

      (Inverter with Converter Assembly Side)

      Check generator (MG1) for an interphase short using a milliohmmeter.


      1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

        Tech Tips

        If the generator (MG1) temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

        Standard Resistance
        for LHD
        Tester Connection Switch Condition Specified Condition
        v3-3 (W) - v3-1 (U) Power switch off 59.2 to 65.2 mΩ
        v3-2 (V) - v3-3 (W) Power switch off 62.2 to 68.2 mΩ
        v3-1 (U) - v3-2 (V) Power switch off 59.2 to 65.2 mΩ
        for RHD
        Tester Connection Switch Condition Specified Condition
        v3-1 (W) - v3-3 (U) Power switch off 59.0 to 65.0 mΩ
        v3-2 (V) - v3-1 (W) Power switch off 61.9 to 67.9 mΩ
        v3-3 (U) - v3-2 (V) Power switch off 59.0 to 65.0 mΩ

        Tech Tips

        To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).


        • R20 = Rt / {1 + 0.00393 X (T - 20)}

        The calculation is based on the following:


        • R20: Resistance at 20°C (68° F) (mΩ)

        • Rt: Measured resistance (mΩ)

        • T: Temperature when the resistance is measured (°C)

    6. When checking for a short circuit between motor phases without using a milliohmmeter.

      Note

      The motor generates current when wheels are rotated by hand. Before performing the inspection, wrap the motor cable terminals with insulation tape.

      Tech Tips

      A short circuit between the motor phases can be checked simply without using a milliohmmeter.


      1. Connect the cable to the negative (-) auxiliary battery terminal.

      2. Turn the power switch on (IG).

        Note

        Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.

      3. Move the shift lever to N.

      4. Lift up the vehicle.

      5. Rotate the rear wheels in the same direction simultaneously by hand.

        Standard
        Left and right wheels rotate smoothly (No short circuit between phases)

        Tech Tips

        If a short circuit exists between the motor phases, the rear wheels do not rotate smoothly (some resistance is felt).

      6. Lower the vehicle.

      7. Move the shift lever to P.

      8. Turn the power switch off.

      9. Disconnect the cable from the negative (-) auxiliary battery terminal.

    7. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      for LHD
      Tester Connection Switch Condition Specified Condition
      v3-3 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      v3-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      v3-1 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      v3-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      v3-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      v3-3 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
    8. Measure the resistance according to the value(s) in the table below.

      Tech Tips

      Perform this procedure only when checking for a short circuit between motor phases without using a milliohmmeter.

      Standard Resistance
      for LHD
      Tester Connection Switch Condition Specified Condition
      v3-3 (W) - v3-2 (V) Power switch off Below 1 Ω
      v3-2 (V) - v3-1 (U) Power switch off Below 1 Ω
      for RHD
      Tester Connection Switch Condition Specified Condition
      v3-1 (W) - v3-2 (V) Power switch off Below 1 Ω
      v3-2 (V) - v3-3 (U) Power switch off Below 1 Ω
    9. Connect the generator cable and motor cable.

    10. Install the inverter terminal cover.


    NG
    OK
  12. CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MG2)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01FVW4E01
      Text in Illustration
      *A for LHD
      *B for RHD

      for Type A:


      1. Remove the inverter terminal cover from the inverter with converter assembly.

    3. A01FUAXE02
      Text in Illustration
      *A for LHD
      *B for RHD

      for Type B:


      1. Remove the inverter terminal cover from the inverter with converter assembly.

    4. A01FUG0E01
      Text in Illustration
      *A for LHD
      *B for RHD
      *1 Motor Cable
      *2 Generator Cable

      Disconnect the generator cable and motor cable from the inverter with converter assembly.

    5. A01FUB2E03
      Text in Illustration
      *A for LHD
      *B for RHD
      *1 Shield Ground
      *a

      Motor Cable

      (Inverter with Converter Assembly Side)

      Check motor (MG2) for an interphase short using a milliohmmeter.


      1. Using a milliohmmeter, measure the resistance according to the value(s) in the table below.

        Tech Tips

        If the motor (MG2) temperature is high, the resistance will vary greatly from the specification. Therefore, measure the resistance at least 8 hours after the vehicle is stopped.

        Standard Resistance
        for LHD
        Tester Connection Switch Condition Specified Condition
        u1-3 (W) - u1-1 (U) Power switch off 47.0 to 51.8 mΩ
        u1-2 (V) - u1-3 (W) Power switch off 47.3 to 52.1 mΩ
        u1-1 (U) - u1-2 (V) Power switch off 47.1 to 51.9 mΩ
        for RHD
        Tester Connection Switch Condition Specified Condition
        u3-1 (W) - u3-3 (U) Power switch off 47.0 to 51.8 mΩ
        u3-2 (V) - u3-1 (W) Power switch off 47.3 to 52.1 mΩ
        u3-3 (U) - u3-2 (V) Power switch off 47.1 to 51.9 mΩ

        Tech Tips

        To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68° F).


        • R20 = Rt / {1 + 0.00393 X (T - 20)}

        The calculation is based on the following:


        • R20: Resistance at 20°C (68° F) (mΩ)

        • Rt: Measured resistance (mΩ)

        • T: Temperature when the resistance is measured (°C)

    6. When checking for a short circuit between motor phases without using a milliohmmeter.

      Note

      The motor generates current when wheels are rotated by hand. Before performing the inspection, wrap the motor cable terminals with insulation tape.

      Tech Tips

      A short circuit between the motor phases can be checked simply without using a milliohmmeter.


      1. Connect the cable to the negative (-) auxiliary battery terminal.

      2. Turn the power switch on (IG).

        Note

        Turning the power switch on (IG) with the service plug grip removed causes other DTCs to be stored. Clear the DTCs after performing this inspection.

      3. Move the shift lever to N.

      4. Lift up the vehicle.

      5. Rotate the rear wheels in the same direction simultaneously by hand.

        Standard
        Left and right wheels rotate smoothly (No short circuit between phases)

        Tech Tips

        If a short circuit exists between the motor phases, the rear wheels do not rotate smoothly (some resistance is felt).

      6. Lower the vehicle.

      7. Move the shift lever to P.

      8. Turn the power switch off.

      9. Disconnect the cable from the negative (-) auxiliary battery terminal.

    7. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      for LHD
      Tester Connection Switch Condition Specified Condition
      u1-3 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      u1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      u1-1 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      u3-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      u3-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      u3-3 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
    8. Measure the resistance according to the value(s) in the table below.

      Tech Tips

      Perform this procedure only when checking for a short circuit between motor phases without using a milliohmmeter.

      Standard Resistance
      for LHD
      Tester Connection Switch Condition Specified Condition
      u1-3 (W) - u1-2 (V) Power switch off Below 1 Ω
      u1-2 (V) - u1-1 (U) Power switch off Below 1 Ω
      for RHD
      Tester Connection Switch Condition Specified Condition
      u3-1 (W) - u3-2 (V) Power switch off Below 1 Ω
      u3-2 (V) - u3-3 (U) Power switch off Below 1 Ω
    9. Connect the generator cable and motor cable.

    10. Install the inverter terminal cover.


    NG
    OK
  13. CHECK FUSE (IGCT NO. 4)


    1. A01FU51E01
      Text in Illustration
      *1 No. 1 Engine Room Relay Block and Junction Block Assembly
      *2 IGCT NO. 4 Fuse

      Remove the IGCT NO. 4 fuse from the No. 1 engine room relay block and junction block assembly.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      IGCT NO. 4 fuse terminal Always Below 1 Ω
    3. Install the IGCT NO. 4 fuse.


    NG
    OK
  14. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY POWER SOURCE CIRCUIT)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD

    3. A01FQOWE19
      Text in Illustration
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-30 (GND1) - Body ground Power switch off Below 1 Ω
      A38-31 (GND2) - Body ground Power switch off Below 1 Ω
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-30 (GND1) - Body ground Power switch off Below 1 Ω
      A74-31 (GND2) - Body ground Power switch off Below 1 Ω
    4. Connect the cable to the negative (-) auxiliary battery terminal.

    5. Turn the power switch on (IG).

    6. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-10 (+B) - Body ground Power switch on (IG) Same as auxiliary battery voltage
      A38-11 (+B2) - Body ground Power switch on (IG) Same as auxiliary battery voltage
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-10 (+B) - Body ground Power switch on (IG) Same as auxiliary battery voltage
      A74-11 (+B2) - Body ground Power switch on (IG) Same as auxiliary battery voltage

      Note

      Turning the power switch on (IG) with the inverter with converter assembly connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    7. Turn the power switch off.

    8. Disconnect the cable from the negative (-) auxiliary battery terminal.

    9. Reconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD


    NG
    OK
  15. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A35 power management control ECU connector.

    3. Disconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD

    4. A01FVP8E07
      Text in Illustration
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      *b

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-23 (HTM+) - A35-34 (HTM+) Power switch off Below 1 Ω
      A38-22 (HTM-) - A35-33 (HTM-) Power switch off Below 1 Ω
      A38-3 (MTH+) - A35-21 (MTH+) Power switch off Below 1 Ω
      A38-2 (MTH-) - A35-20 (MTH-) Power switch off Below 1 Ω
      A38-34 (REQ+) - A35-32 (REQ+) Power switch off Below 1 Ω
      A38-33 (REQ-) - A35-31 (REQ-) Power switch off Below 1 Ω
      A38-14 (CLK+) - A35-29 (CLK+) Power switch off Below 1 Ω
      A38-13 (CLK-) - A35-28 (CLK-) Power switch off Below 1 Ω
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-23 (HTM+) - A35-34 (HTM+) Power switch off Below 1 Ω
      A74-22 (HTM-) - A35-33 (HTM-) Power switch off Below 1 Ω
      A74-3 (MTH+) - A35-21 (MTH+) Power switch off Below 1 Ω
      A74-2 (MTH-) - A35-20 (MTH-) Power switch off Below 1 Ω
      A74-34 (REQ+) - A35-32 (REQ+) Power switch off Below 1 Ω
      A74-33 (REQ-) - A35-31 (REQ-) Power switch off Below 1 Ω
      A74-14 (CLK+) - A35-29 (CLK+) Power switch off Below 1 Ω
      A74-13 (CLK-) - A35-28 (CLK-) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-23 (HTM+) or A35-34 (HTM +) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-22 (HTM-) or A35-33 (HTM-) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-3 (MTH+) or A35-21 (MTH+) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-2 (MTH-) or A35-20 (MTH-) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-34 (REQ+) or A35-32 (REQ+) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-33 (REQ-) or A35-31 (REQ-) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-14 (CLK+) or A35-29 (CLK+) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-13 (CLK-) or A35-28 (CLK-) - Body ground and other terminals Power switch off 10 kΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-23 (HTM+) or A35-34 (HTM +) - Body ground and other terminals Power switch off 10 kΩ or higher
      A74-22 (HTM-) or A35-33 (HTM-) - Body ground and other terminals Power switch off 10 kΩ or higher
      A74-3 (MTH+) or A35-21 (MTH+) - Body ground and other terminals Power switch off 10 kΩ or higher
      A74-2 (MTH-) or A35-20 (MTH-) - Body ground and other terminals Power switch off 10 kΩ or higher
      A74-34 (REQ+) or A35-32 (REQ+) - Body ground and other terminals Power switch off 10 kΩ or higher
      A74-33 (REQ-) or A35-31 (REQ-) - Body ground and other terminals Power switch off 10 kΩ or higher
      A74-14 (CLK+) or A35-29 (CLK+) - Body ground and other terminals Power switch off 10 kΩ or higher
      A74-13 (CLK-) or A35-28 (CLK-) - Body ground and other terminals Power switch off 10 kΩ or higher
    5. Connect the cable to the negative (-) auxiliary battery terminal.

    6. Turn the power switch on (IG).

    7. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-23 (HTM+) or A35-34 (HTM+) - Body ground Power switch on (IG) Below 1 V
      A38-22 (HTM-) or A35-33 (HTM-) - Body ground Power switch on (IG) Below 1 V
      A38-3 (MTH+) or A35-21 (MTH+) - Body ground Power switch on (IG) Below 1 V
      A38-2 (MTH-) or A35-20 (MTH-) - Body ground Power switch on (IG) Below 1 V
      A38-34 (REQ+) or A35-32 (REQ+) - Body ground Power switch on (IG) Below 1 V
      A38-33 (REQ-) or A35-31 (REQ-) - Body ground Power switch on (IG) Below 1 V
      A38-14 (CLK+) or A35-29 (CLK+) - Body ground Power switch on (IG) Below 1 V
      A38-13 (CLK-) or A35-28 (CLK-) - Body ground Power switch on (IG) Below 1 V
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-23 (HTM+) or A35-34 (HTM+) - Body ground Power switch on (IG) Below 1 V
      A74-22 (HTM-) or A35-33 (HTM-) - Body ground Power switch on (IG) Below 1 V
      A74-3 (MTH+) or A35-21 (MTH+) - Body ground Power switch on (IG) Below 1 V
      A74-2 (MTH-) or A35-20 (MTH-) - Body ground Power switch on (IG) Below 1 V
      A74-34 (REQ+) or A35-32 (REQ+) - Body ground Power switch on (IG) Below 1 V
      A74-33 (REQ-) or A35-31 (REQ-) - Body ground Power switch on (IG) Below 1 V
      A74-14 (CLK+) or A35-29 (CLK+) - Body ground Power switch on (IG) Below 1 V
      A74-13 (CLK-) or A35-28 (CLK-) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the power management control ECU and inverter with converter assembly connectors disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    8. Turn the power switch off.

    9. Disconnect the cable from the negative (-) auxiliary battery terminal.

    10. Reconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD

    11. Reconnect the A35 power management control ECU connector.


    NG
    OK
  16. CHECK POWER MANAGEMENT CONTROL ECU


    1. Disconnect the A35 power management control ECU connector.

    2. A01FQMYE01
      Text in Illustration
      *a

      Component without harness connected

      (Power Management Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      A35-34 (HTM+) - A35-33 (HTM-) Power switch off 80 to 170 Ω
      A35-21 (MTH+) - A35-20 (MTH-) Power switch off 80 to 170 Ω
      A35-32 (REQ+) - A35-31 (REQ-) Power switch off 80 to 170 Ω
      A35-29 (CLK+) - A35-28 (CLK-) Power switch off 80 to 170 Ω
    3. Reconnect the A35 power management control ECU connector.


    NG
    OK
  17. CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    1. A01FS4V

      Remove the hybrid vehicle transmission assembly Click here.

    2. Check the connection condition of the generator resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter Click here.

      OK
      - The connector is connected securely.
      - The terminals are not deformed and are connected securely.
      - No water or foreign matter in the connector.
      Result
      Result Proceed to
      OK A
      NG (The connector is not connected securely.) B
      NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C

    B
    C
    A
  18. CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    1. A01FT1X

      Check the connection condition of the motor resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter Click here.

      OK
      - The connector is connected securely.
      - The terminals are not deformed and are connected securely.
      - No water or foreign matter in the connector.
      Result
      Result Proceed to
      OK A
      NG (The connector is not connected securely.) B
      NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C
    2. Install the hybrid vehicle transmission assembly.


    B
    C
    A
  19. CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    1. Remove the hybrid vehicle transmission assembly Click here.

    2. A01FS4V

      Check the connection condition of the generator resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter Click here.

      OK
      - The connector is connected securely.
      - The terminals are not deformed and are connected securely.
      - No water or foreign matter in the connector.
      Result
      Result Proceed to
      OK A
      NG (The connector is not connected securely.) B
      NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C

    B
    C
    A
  20. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD

    3. Disconnect the F50 generator resolver connector.

    4. A01FT2DE03
      Text in Illustration
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Generator Resolver)

      *b

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-20 (GRF) - F50-1 (GRF) Power switch off Below 1 Ω
      A38-9 (GRFG) - F50-5 (GRFG) Power switch off Below 1 Ω
      A38-18 (GSN) - F50-2 (GSN) Power switch off Below 1 Ω
      A38-7 (GSNG) - F50-6 (GSNG) Power switch off Below 1 Ω
      A38-17 (GCS) - F50-3 (GCS) Power switch off Below 1 Ω
      A38-6 (GCSG) - F50-7 (GCSG) Power switch off Below 1 Ω
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-20 (GRF) - F50-1 (GRF) Power switch off Below 1 Ω
      A74-9 (GRFG) - F50-5 (GRFG) Power switch off Below 1 Ω
      A74-18 (GSN) - F50-2 (GSN) Power switch off Below 1 Ω
      A74-7 (GSNG) - F50-6 (GSNG) Power switch off Below 1 Ω
      A74-17 (GCS) - F50-3 (GCS) Power switch off Below 1 Ω
      A74-6 (GCSG) - F50-7 (GCSG) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-20 (GRF) or F50-1 (GRF) - Body ground and other terminals Power switch off 1 MΩ or higher
      A38-9 (GRFG) or F50-5 (GRFG) - Body ground and other terminals Power switch off 1 MΩ or higher
      A38-18 (GSN) or F50-2 (GSN) - Body ground and other terminals Power switch off 1 MΩ or higher
      A38-7 (GSNG) or F50-6 (GSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
      A38-17 (GCS) or F50-3 (GCS) - Body ground and other terminals Power switch off 1 MΩ or higher
      A38-6 (GCSG) or F50-7 (GCSG) - Body ground and other terminals Power switch off 1 MΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-20 (GRF) or F50-1 (GRF) - Body ground and other terminals Power switch off 1 MΩ or higher
      A74-9 (GRFG) or F50-5 (GRFG) - Body ground and other terminals Power switch off 1 MΩ or higher
      A74-18 (GSN) or F50-2 (GSN) - Body ground and other terminals Power switch off 1 MΩ or higher
      A74-7 (GSNG) or F50-6 (GSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
      A74-17 (GCS) or F50-3 (GCS) - Body ground and other terminals Power switch off 1 MΩ or higher
      A74-6 (GCSG) or F50-7 (GCSG) - Body ground and other terminals Power switch off 1 MΩ or higher

      Tech Tips

      The generator resolver is not available as a supply part. If it requires replacement, replace the hybrid vehicle transmission assembly.

    5. Reconnect the F50 generator resolver connector.

    6. Reconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD


    NG
    OK
  21. CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    1. Remove the hybrid vehicle transmission assembly Click here.

    2. A01FT1X

      Check the connection condition of the motor resolver connector and the contact pressure of each terminal. Check the terminals for deformation, and check the connector for water ingress and foreign matter Click here.

      OK
      - The connector is connected securely.
      - The terminals are not deformed and are connected securely.
      - No water or foreign matter in the connector.
      Result
      Result Proceed to
      OK A
      NG (The connector is not connected securely.) B
      NG (The terminals are not making secure contact or are deformed, or water or foreign matter exists in the connector.) C

    B
    C
    A
  22. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD

    3. Disconnect the F51 motor resolver connector.

    4. A01FT2DE04
      Text in Illustration
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Motor Resolver)

      *b

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-40 (MRF) - F51-1 (MRF) Power switch off Below 1 Ω
      A38-29 (MRFG) - F51-5 (MRFG) Power switch off Below 1 Ω
      A38-39 (MSN) - F51-2 (MSN) Power switch off Below 1 Ω
      A38-28 (MSNG) - F51-6 (MSNG) Power switch off Below 1 Ω
      A38-38 (MCS) - F51-3 (MCS) Power switch off Below 1 Ω
      A38-27 (MCSG) - F51-7 (MCSG) Power switch off Below 1 Ω
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-40 (MRF) - F51-1 (MRF) Power switch off Below 1 Ω
      A74-29 (MRFG) - F51-5 (MRFG) Power switch off Below 1 Ω
      A74-39 (MSN) - F51-2 (MSN) Power switch off Below 1 Ω
      A74-28 (MSNG) - F51-6 (MSNG) Power switch off Below 1 Ω
      A74-38 (MCS) - F51-3 (MCS) Power switch off Below 1 Ω
      A74-27 (MCSG) - F51-7 (MCSG) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-40 (MRF) or F51-1 (MRF) - Body ground and other terminals Power switch off 1 MΩ or higher
      A38-29 (MRFG) or F51-5 (MRFG) - Body ground and other terminals Power switch off 1 MΩ or higher
      A38-39 (MSN) or F51-2 (MSN) - Body ground and other terminals Power switch off 1 MΩ or higher
      A38-28 (MSNG) or F51-6 (MSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
      A38-38 (MCS) or F51-3 (MCS) - Body ground and other terminals Power switch off 1 MΩ or higher
      A38-27 (MCSG) or F51-7 (MCSG) - Body ground and other terminals Power switch off 1 MΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-40 (MRF) or F51-1 (MRF) - Body ground and other terminals Power switch off 1 MΩ or higher
      A74-29 (MRFG) or F51-5 (MRFG) - Body ground and other terminals Power switch off 1 MΩ or higher
      A74-39 (MSN) or F51-2 (MSN) - Body ground and other terminals Power switch off 1 MΩ or higher
      A74-28 (MSNG) or F51-6 (MSNG) - Body ground and other terminals Power switch off 1 MΩ or higher
      A74-38 (MCS) or F51-3 (MCS) - Body ground and other terminals Power switch off 1 MΩ or higher
      A74-27 (MCSG) or F51-7 (MCSG) - Body ground and other terminals Power switch off 1 MΩ or higher

      Tech Tips

      The motor resolver is not available as a supply part. If it requires replacement, replace the hybrid vehicle transmission assembly.

    5. Reconnect the F51 motor resolver connector.

    6. Reconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD


    NG
    OK
  23. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - IGCT NO. 4 FUSE)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD

    3. A01FQOWE20
      Text in Illustration
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-10 (+B) - Body ground Power switch off 10 kΩ or higher
      A38-11 (+B2) - Body ground Power switch off 10 kΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-10 (+B) - Body ground Power switch off 10 kΩ or higher
      A74-11 (+B2) - Body ground Power switch off 10 kΩ or higher
    4. Reconnect the A38*1 or A74*2 inverter with converter assembly connector.


      • *1: for LHD

      • *2: for RHD


    NG
    OK
  24. REPLACE INVERTER WITH CONVERTER ASSEMBLY

    Click here


    NEXT
  25. REPAIR OR REPLACE HARNESS OR CONNECTOR


    NEXT
  26. CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (GENERATOR CABLE CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the hybrid vehicle transmission assembly Click here.

    3. A01FPZJ

      Check that the bolts for the generator cable are tightened to the specified torque, the generator cable is connected securely, and there are no contact problems.

      Specified Condition
      T=8.0 N*m (82 kgf*cm, 71 in.*lbf)

      Note

      Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

    4. Disconnect the generator cable from the hybrid vehicle transmission assembly.

    5. Check for arc marks at the terminals for the generator cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    6. Connect the generator cable to the hybrid vehicle transmission assembly.

    7. Install the hybrid vehicle transmission assembly.


    B
    C
    A
  27. CHECK GENERATOR CABLE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the generator cable Click here.

    3. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      A01FURVE03
      Text in Illustration
      *A for LHD *B for RHD
      *1 Shield ground - -
      *a

      Generator Cable

      (Inverter with Converter Assembly Side)

      *b

      Generator Cable

      (Hybrid Vehicle Transmission Assembly Side)

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      for LHD
      Tester Connection Switch Condition Specified Condition
      v3-3 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      v3-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      v3-1 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      v3-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      v3-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      v3-3 (U) - Body ground and shield ground Power switch off 100 MΩ or higher

      Note

      Wrap the terminal of the generator cable with insulating tape to prevent them from coming into contact with body ground.

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Switch Condition Specified Condition
      v3-3 (W) - v4-3 (U) Power switch off 100 MΩ or higher
      v3-2 (V) - v4-1 (W) Power switch off 100 MΩ or higher
      v3-1 (U) - v4-2 (V) Power switch off 100 MΩ or higher
      v3-3 (W) - v4-1 (W) Power switch off Below 1 Ω
      v3-2 (V) - v4-2 (V) Power switch off Below 1 Ω
      v3-1 (U) - v4-3 (U) Power switch off Below 1 Ω
      for RHD
      Tester Connection Switch Condition Specified Condition
      v3-1 (W) - v4-3 (U) Power switch off 100 MΩ or higher
      v3-2 (V) - v4-1 (W) Power switch off 100 MΩ or higher
      v3-3 (U) - v4-2 (V) Power switch off 100 MΩ or higher
      v3-1 (W) - v4-1 (W) Power switch off Below 1 Ω
      v3-2 (V) - v4-2 (V) Power switch off Below 1 Ω
      v3-3 (U) - v4-3 (U) Power switch off Below 1 Ω
    5. Install the generator cable.


    NG
    OK
  28. CHECK HYBRID VEHICLE TRANSMISSION ASSEMBLY (MOTOR CABLE CONNECTION CONDITION)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the hybrid vehicle transmission assembly Click here.

    3. A01FQ7H

      Check that the bolts for the motor cable are tightened to the specified torque, the motor cable is connected securely, and there are no contact problems.

      Specified Condition
      T=8.0 N*m (82 kgf*cm, 71 in.*lbf)

      Note

      Make sure that the tightening torque of the bolt is between 6.4 and 9.6 N*m (65 and 98 kgf*cm, 57 and 85 in.*lbf).

    4. Disconnect the motor cable from the hybrid vehicle transmission assembly.

    5. Check for arc marks at the terminals for the motor cable.

      Result
      Result Proceed to
      The terminals are connected securely and there are no contact problems. There are no arc marks. A
      The terminals are not connected securely and there is a contact problem. There are arc marks. B
      The terminals are not connected securely and there is a contact problem. There are no arc marks. C
      The terminals are connected securely and there are no contact problems. There are arc marks. B
    6. Connect the motor cable to the hybrid vehicle transmission assembly.

    7. Install the hybrid vehicle transmission assembly.


    B
    C
    A
  29. CHECK MOTOR CABLE

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Remove the motor cable Click here.

    3. Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.

      A01FSFVE02
      Text in Illustration
      *A for LHD *B for RHD
      *1 Shield ground - -
      *a

      Motor Cable

      (Inverter with Converter Assembly Side)

      *b

      Motor Cable

      (Hybrid Vehicle Transmission Assembly Side)

      Note

      Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.

      Standard Resistance
      for LHD
      Tester Connection Switch Condition Specified Condition
      u1-3 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      u1-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      u1-1 (U) - Body ground and shield ground Power switch off 100 MΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      u3-1 (W) - Body ground and shield ground Power switch off 100 MΩ or higher
      u3-2 (V) - Body ground and shield ground Power switch off 100 MΩ or higher
      u3-3 (U) - Body ground and shield ground Power switch off 100 MΩ or higher

      Note

      Wrap the terminal of the motor cable with insulating tape to prevent them from coming into contact with body ground.

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      for LHD
      Tester Connection Switch Condition Specified Condition
      u1-3 (W) - u2-1 (U) Power switch off 100 MΩ or higher
      u1-2 (V) - u2-3 (W) Power switch off 100 MΩ or higher
      u1-1 (U) - u2-2 (V) Power switch off 100 MΩ or higher
      u1-3 (W) - u2-3 (W) Power switch off Below 1 Ω
      u1-2 (V) - u2-2 (V) Power switch off Below 1 Ω
      u1-1 (U) - u2-1 (U) Power switch off Below 1 Ω
      for RHD
      Tester Connection Switch Condition Specified Condition
      u3-1 (W) - u2-1 (U) Power switch off 100 MΩ or higher
      u3-2 (V) - u2-3 (W) Power switch off 100 MΩ or higher
      u3-3 (U) - u2-2 (V) Power switch off 100 MΩ or higher
      u3-1 (W) - u2-3 (W) Power switch off Below 1 Ω
      u3-2 (V) - u2-2 (V) Power switch off Below 1 Ω
      u3-3 (U) - u2-1 (U) Power switch off Below 1 Ω
    5. Install the motor cable.


    NG
    OK