| DTC Code | DTC Name |
|---|---|
| P0A02-719 | Motor Electronics Coolant Temperature Sensor Circuit Low |
| P0A03-720 | Motor Electronics Coolant Temperature Sensor Circuit High |
DESCRIPTION
Refer to the description for DTC P0A01-726 Click here.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0A02-719 | Short to GND in the HV coolant temperature sensor circuit (1 trip detection logic) |
Inverter with converter assembly |
| P0A03-720 | Open or short to +B in the HV coolant temperature sensor circuit (1 trip detection logic) |
| DTC No. | Data List |
|---|---|
| P0A02-719 | Inverter Coolant Water Temperature |
| P0A03-720 |
INSPECTION PROCEDURE
Tech Tips
After the repair, clear the DTCs. If "Inverter Coolant Water Temperature" does not show an abnormal value (110°C (230°F) or -50°C (-58°F)) when the power switch is turned on (IG), the condition is judged as normal.
(If a Low malfunction exists in the HV coolant temperature sensor wiring, 110°C (230°F) is displayed and if a High malfunction exists, -50°C (-58°F) is displayed.)