СИСТЕМА УПРАВЛЕНИЯ ГИБРИДНОЙ СИСТЕМОЙ, Diagnostic DTC:P0516-769, P0517-770

DTC Code DTC Name
P0516-769 Battery Temperature Sensor Circuit Low
P0517-770 Battery Temperature Sensor Circuit High

DESCRIPTION


DTC No. DTC Detection Condition Trouble Area
P0516-769

Malfunction in the thermistor assembly circuit (short to GND)

(1 trip detection logic)


  • Thermistor assembly

  • Wire harness or connector

  • Power management control ECU

P0517-770

Malfunction in the thermistor assembly circuit (open or short to +B)

(1 trip detection logic)

Related Data List
DTC No. Data List
P0516-769 Auxiliary Batt Temperature
P0517-770

WIRING DIAGRAM

A01FV4EE18

INSPECTION PROCEDURE

Tech Tips


  • Read the freeze frame data using the GTS. In the freeze frame data, some information is recorded about the vehicle conditions at the moment a malfunction occurred. This information can be helpful when troubleshooting.

  • After confirming that DTC P0516-769 or P0517-770 is output, use the GTS to check "Auxiliary Batt Temperature" in the Hybrid Control Data List.

    Displayed Temperature Malfunction
    -40°C (-40°F) Open circuit or short to +B
    215°C (419°F) Short circuit or short to GND
  • After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.


    1. Turn the power switch on (IG) and wait for 5 seconds or more.

PROCEDURE


  1. CHECK CONNECTOR CONNECTION CONDITION (POWER MANAGEMENT CONTROL ECU CONNECTOR)


    1. A01FQC6E01
      Text in Illustration
      *A for LHD
      *B for RHD

      Check the connector connections and contact pressure of the relevant terminals for the power management control ECU connectors Click here.

      OK
      The connectors are connected securely and there are no contact pressure problems.

    NG
    OK
  2. READ VALUE USING GTS (AUXILIARY BATT TEMPERATURE)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Data List / Auxiliary Batt Temperature.

    4. Read the Data List.

      Result
      Result Proceed to
      -40°C (-40°F) A
      215°C (419°F) B
      Same as actual temperature C
    5. Turn the power switch off.


    B
    C
    A
  3. READ VALUE USING GTS (CHECK FOR OPEN)


    1. A01FRUC

      Disconnect the U44 thermistor assembly connector.

    2. A01FVX7E20

      Connect terminals 2 (THB) and 1 (E2) of the vehicle side of the U44 thermistor assembly connector.

    3. Connect the GTS to the DLC3.

    4. Turn the power switch on (IG).

    5. Enter the following menus: Powertrain / Hybrid Control / Data List / Auxiliary Batt Temperature.

    6. Read the Data List.

      OK
      Tester Display Condition Specified Condition
      Auxiliary Batt Temperature Terminals THB and E2 connected. Power switch on (IG) 215°C (419°F)
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Thermistor Assembly)

    7. Turn the power switch off.

    8. Reconnect the U44 thermistor assembly connector.


    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - THERMISTOR ASSEMBLY)


    1. A01FV0LE37
      Text in Illustration
      *a

      Component with harness connected

      (Power Management Control ECU)

      Connect terminals 27 (THB) and 26 (ETHB) of the N91 power management control ECU connector.

    2. Connect the GTS to the DLC3.

    3. Turn the power switch on (IG).

    4. Enter the following menus: Powertrain / Hybrid Control / Data List / Auxiliary Batt Temperature.

    5. Read the Data List.

      OK
      Tester Display Condition Specified Condition
      Auxiliary Batt Temperature Terminals THB and ETHB connected. Power switch on (IG) 215°C (419°F)
    6. Turn the power switch off.


    NG
    OK
  5. READ VALUE USING GTS (CHECK FOR SHORT)


    1. A01FRUC

      Disconnect the U44 thermistor assembly connector.

    2. Connect the GTS to the DLC3.

    3. Turn the power switch on (IG).

    4. Enter the following menus: Powertrain / Hybrid Control / Data List / Auxiliary Batt Temperature.

    5. Read the Data List.

      OK
      Tester Display Switch Condition Specified Condition
      Auxiliary Batt Temperature Power switch on (IG) -40°C (-40°F)
    6. Turn the power switch off.

    7. Reconnect the U44 thermistor assembly connector.


    NG
    OK
  6. CHECK HARNESS AND CONNECTOR (THERMISTOR ASSEMBLY - POWER MANAGEMENT CONTROL ECU)


    1. Disconnect the U44 thermistor assembly connector.

    2. Disconnect the N91 power management control ECU connector.

    3. A01FVM9E02
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Thermistor Assembly)

      *b

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Check for Open
      Tester Connection Switch Condition Specified Condition
      U44-2 (THB) - N91-27 (THB) Power switch off Below 1 Ω
      U44-1 (E2) - N91-26 (ETHB) Power switch off Below 1 Ω
      Check for Short
      Tester Connection Switch Condition Specified Condition
      U44-2 (THB) or N91-27 (THB) - Body ground and other terminals Power switch off 10 kΩ or higher
      U44-1 (E2) or N91-26 (ETHB) - Body ground and other terminals Power switch off 10 kΩ or higher
    4. Reconnect the N91 power management control ECU connector.

    5. Reconnect the U44 thermistor assembly connector.


    NG
    OK