LUGGAGE COMPARTMENT DOOR OPENER MAIN SWITCH INSPECTION

PROCEDURE


  1. INSPECT LUGGAGE DOOR OPENING CANCEL SWITCH ASSEMBLY


    1. A004HZEE01
      Text in Illustration
      *a

      Component without harness connected

      (Luggage Door Opening Cancel Switch Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      1 - 2 Pushed (ON) Below 1 Ω
      1 - 2 Not pushed (OFF) 10 kΩ or higher

      If the result is not as specified, replace the switch assembly.