AIR CONDITIONING SYSTEM(for Automatic Air Conditioning System) DATA LIST / ACTIVE TEST


  1. DATA LIST

    Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    Note

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    5. Check the value(s) by referring to the table below.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note

      Room Temperature Sensor

      (Room Temp)

      Room temperature sensor /

      Min.: -72.47°C (-98.4°F)

      Max.: 193.82°C (380.9°F)

      Actual cabin temperature displayed -

      Solar Sensor

      (Solar Sens)

      Solar sensor /

      Min.: 0W/m2

      Max.: 4448W/m2

      Solar sensor value increases as brightness increases -

      Pressure Switch Operation

      (Pressure Switch Oper)

      Pressure Switch /

      Normal.: 0

      Abnormal.: 225

      - -

      Engine Coolant Temp

      (Coolant Temp)

      Engine coolant temperature sensor /

      Min.: -40.00°C (-40.00°F)

      Max.: 215.00°C (419°F)

      Actual engine coolant temperature is displayed -

      Set Temperature (D Side)

      (Set Temp-D)

      Driver side set temperature /

      Min.: 18.00°C (64.40°F)

      Max.: 32.00°C (89.60°F)

      Driver side set temperature displayed -

      Set Temperature (P Side)

      (Set Temp-P)

      Passenger side set temperature /

      Min.: 18°C (65°F)

      Max.: 32°C (85°F)

      Passenger side set temperature displayed -

      Air Outlet Servo Temp (D Side)

      (Air Out Serv Temp-D)

      Driver side air outlet temperature /

      Min.: -327.68°C (-557.8°F)

      Max.: 327.67°C (621.8°F)

      Driver side air outlet temperature displayed -

      Air Outlet Servo Temp (P Side)

      (Air Out Serv Temp-P)

      Passenger side air outlet temperature /

      Min.: -327.68°C (-557.8°F)

      Max.: 327.67°C (621.8°F)

      Passenger side air outlet temperature displayed -

      Air Mix Damper Position (D)

      (A/M Damp Pos-D)

      Driver side air mix damper position /

      Min.: -32.68%

      Max.: -133.33%

      MAX. COLD: 0%

      MAX. HOT: 110%

      -

      Air Mix Damper Position (P)

      (A/M Damp Pos-P)

      Passenger side air mix damper position /

      Min.: -32.68%

      Max.: -133.33%

      MAX. COLD: 0%

      MAX. HOT: 110%

      -

      Air Outlet Damper Position

      (A/O Damp Pos)

      Air outlet damper position /

      Min.: -32.68%

      Max.: -133.33%

      FACE: -16.7%

      B/L: 10%

      FOOT-0: 50% (Manual operation)

      FOOT: 70%

      FOOT/DEF: 90%

      DEF: 116.7%

      -

      Air Inlet Damper Position

      (A/I Damp Pos)

      Air inlet damper position /

      Min.: 0

      Max.: 100

      Inside: 0

      Outside: 100

      -

      Air Mix Damper Target (D)

      (A/M Damp Targ-D)

      Driver side air mix damper target position /

      Min.: -32.68%

      Max.: 133.33%

      MAX. COLD: 0%

      MAX. HOT: 110%

      -

      Air Mix Damper Target (P)

      (A/M Damp Targ-P)

      Passenger side air mix damper target position /

      Min.: -32.68%

      Max.: 133.33%

      MAX. COLD: 0%

      MAX. HOT: 110%

      -

      Air Outlet Damper Target

      (A/O Damp Targ)

      Air outlet damper target position /

      Min.: -32.68%

      Max.: 133.33%

      FACE: -16.7%

      B/L: 10%

      FOOT-0: 50% (Manual operation)

      FOOT: 70%

      FOOT/DEF: 90%

      DEF: 116.7%

      -

      Air Inlet Damper Target

      (A/I Damp Targ)

      Air outlet damper target position /

      REC or FRC

      Inside: REC

      Outside: FRC

      -

      Blower Motor Speed Level

      (Blower Level)

      Blower motor speed level /

      Min.: 0

      Max.: 31

      Displayed speed level increases in range between 0 and 31 as blower motor speed increases -

      Ambient Temp Sensor

      (Ambi Temp Sens)

      Ambient temperature sensor (thermistor assembly) /

      Min.: -40.00°C (-40.00°F)

      Max.: 80.00°C (176.00°F)

      Actual ambient temperature displayed -

      Status of Compressor Operation

      (Stat of Compre Oper)

      Status of compressor operation

      ON or OFF

      Compressor operation ON: ON

      Compressor operation OFF: OFF

      -

      Status of Blower Fan Operation

      (Status Blow Fan Oper)

      Status of blower fan operation

      Manual or Auto

      Blower fan manual operation: Manual

      Blower fan auto operation: Auto

      -

      Status of Air Conditioner Operation

      (Status Air Cond Oper)

      Status of air conditioner operation

      Manual or Auto

      Air conditioner manual operation: Manual

      Air conditioner Auto operation: Auto

      -

      Status of Air Inlet Damper Operation

      (Sta Air Inl Damp Ope)

      Status of air inlet damper operation

      Manual or Auto

      Air inlet damper manual operation: Manual

      Air inlet damper Auto operation: Auto

      -

      Status of Air Outlet Damper Operation

      (Sta Air Out Damp Ope)

      Status of air outlet damper operation

      Manual or Auto

      Air outlet damper manual operation: Manual

      Air outlet damper Auto operation: Auto

      -

      Defogger Relay (Rear)

      (Defogger Relay Rr)

      Rear window defogger operation

      ON or OFF

      Rear window defogger operation ON: ON

      Rear window defogger operation OFF: OFF

      -

      Engine Spd

      (Engin Spd)

      Engine speed

      Min.: 0 rpm

      Max.: 32767 rpm

      - -

      Vehicle Spd

      (Vehic Spd)

      Vehicle speed

      Min.: 0.00 km/h

      Max.: 300.00 km/h

      - -

      Evaporator Temp Sensor

      (Evap Temp)

      Evaporator temperature sensor (No. 1 cooler thermistor) /

      Min.: -82.48°C (-116.46°F)

      Max.: 153.55°C (308.39°F)

      Actual evaporator temperature displayed -

      Evaporator Target Temp

      (Evap Tag Temp)

      Evaporator temperature sensor (No. 1 cooler thermistor) /

      Min.: 0.00°C (32.0°F)

      Max.: 20.00°C (68.0°F)

      - -

      Air Inlet Mode

      (Air Inlet Mode)

      Air inlet mode /

      Auto or Manual

      Customized value displayed -

      Compressor/Air Inlet DEF Operation

      (Comprs/DEF Oper)

      Compressor/air inlet DEF operation /

      Link or Normal

      Customized value displayed -

      DEF (PSW/Lock) Mode Setting

      (DEF (PSW/Lock) Md Set)

      DEF (PSW/Lock) mode setting

      Link or Normal

      Customized value displayed -

      Foot/DEF Automatic Blow Up Function

      (Auto Blow Up)

      Foot/DEF Automatic Blow Up Function

      ON or OFF

      Customized value displayed -

      Foot/DEF Auto Mode

      (Foot/DEF Mode)

      Foot/DEF auto mode /

      Auto or Manual

      Customized value displayed -

      Set Temperature Shift

      (Set Temp Shift)

      Set temperature shift

      Min.: -3°C

      Max.: +3°C

      Customized value displayed -

      Number of Trouble Codes

      (#Codes)

      Number of trouble codes /

      Min.: 0

      Max.: 255

      Number of DTCs displayed -

      • *1: for Driver side

      • *2: for Front passenger side

  2. ACTIVE TEST

    Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON.

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

    5. Check the operation by referring to the table below.

      Air Conditioner
      Tester Display Test Part Control Range Diagnostic Note
      Blower Motor Blower motor with fan sub-assembly Min.: 0, Max.: 31 -
      Air Mix Damper (D) No. 5 air conditioning radiator damper servo sub-assembly (air mix*1)

      Min.: 0.00, Max.: 110.00

      Note

      Operation outside this range may result in damage. Make sure that the active test is performed within the regular range.

      -
      Air Mix Damper (P) No. 4 air conditioning radiator damper servo sub-assembly (air mix*2)

      Min.: 0.00, Max.: 110.00

      Note

      Operation outside this range may result in damage. Make sure that the active test is performed within the regular range.

      -
      Air Outlet Damper No. 1 air conditioning radiator damper servo sub-assembly (air outlet) Min.: -16.7, Max.: 116.7 -
      Solar Sensor Solar Sensor Min.: 0, Max.: 4448 -
      Auto Switch Auto Switch OFF, ON -
      Defogger Relay (Rear) Defogger relay (engine room relay block assembly) OFF, ON -
      Magnetic Clutch Relay A/C system operation OFF, ON -
      Inside and Outside Change Blower damper servo sub-assembly (air inlet) Inside, Outside -

      • *1: for Driver side

      • *2: for Front passenger side