DESCRIPTION
This circuit is the power source circuit for the combination meter assembly.
WIRING DIAGRAM
| *a | MAIN Fuse |
| *b | IG2 Relay |
| *c | GAUGE |
| *d | COMBINATION METER ASSEMBLY |
CAUTION / NOTICE / HINT
Note
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
CHECK HARNESS AND CONNECTOR (COMBINATION METER ASSEMBLY - BATTERY AND BODY GROUND)
| *a | Front view of wire harness connector (to Combination Meter Assembly) |
Disconnect the D7 combination meter assembly connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Measure the resistance according to the value in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Reconnect the D7 combination meter assembly connector.
| OK |
|
REPLACE COMBINATION METER ASSEMBLY Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |