FRONT DOOR LOCK INSPECTION

PROCEDURE


  1. REMOVE FRONT DOOR LOCK ASSEMBLY LH (w/o Double Locking System)

    A004IRDE26
    Text in Illustration
    *a

    Component without harness connected

    (Front Door Lock Assembly LH)

    *b Unlock
    *c Lock

    1. Check the operation of the door lock motor.


      1. Apply battery voltage and check the operation of the door lock motor.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → 4 (L)

        Battery negative (-) → 1 (UL)

        Lock

        Battery positive (+) → 1 (UL)

        Battery negative (-) → 4 (L)

        Unlock

        If the result is not as specified, replace the front door lock assembly LH.

    2. A004IRDE27
      Text in Illustration
      *a

      Component without harness connected

      (Front Door Lock Assembly LH)

      *b Unlock
      *c Lock

      Check the operation of the door unlock detection switch (w/ Entry and Start System for LHD).


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        7 (E) - 8 (LSSR) Lock 10 kΩ or higher
        7 (E) - 8 (LSSR) Unlock Below 1 Ω

        If the result is not as specified, replace the front door lock assembly LH.

    3. A004IRDE27
      Text in Illustration
      *a

      Component without harness connected

      (Front Door Lock Assembly LH)

      *b Unlock
      *c Lock

      Check the operation of the door unlock detection switch (w/ Entry and Start System for RHD).


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        7 (E) - 8 (LSSR) Lock 10 kΩ or higher
        7 (E) - 8 (LSSR) Unlock Below 1 Ω

        If the result is not as specified, replace the front door lock assembly LH.

  2. INSPECT FRONT DOOR LOCK ASSEMBLY LH (w/ Double Locking System)

    A004IS6E11
    Text in Illustration
    *a

    Component without harness connected

    (Front Door Lock Assembly LH)

    *b Unlock
    *c Lock

    1. Check the door lock motor operation.


      1. Apply battery voltage to the motor connector and check the operation of the front door lock motor.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → 4 (L)

        Battery negative (-) → 3 (UL)

        Lock

        Battery positive (+) → 3 (UL)

        Battery negative (-) → 4 (L)

        Unlock

        Battery positive (+) → 2 (L)

        Battery negative (-) → 1 (UL)

        Set

        Battery positive (+) → 1 (UL)

        Battery negative (-) → 2 (L)

        Unset

        Tech Tips


        • Move the door lock motor to the lock position and set the double locking system. Check that the doors cannot be unlocked by operating the control cable.

        • Move the door lock motor to the lock position and unset the double locking system. Check that the doors can be unlocked by operating the control cable.


        • If the result is not as specified, replace the front door lock assembly LH.

  3. INSPECT FRONT DOOR LOCK ASSEMBLY RH (w/o Double Locking System)

    A004IJ3E29
    Text in Illustration
    *a

    Component without harness connected

    (Front Door Lock Assembly RH)

    *b Unlock
    *c Lock

    1. Check the door lock motor operation.


      1. Apply battery voltage to the door lock motor connector and check the operation of the door lock motor.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → 4 (L)

        Battery negative (-) → 1 (UL)

        Lock

        Battery positive (+) → 1 (UL)

        Battery negative (-) → 4 (L)

        Unlock

        • If the result is not as specified, replace the front door lock assembly RH.

    2. A004IAWE02
      Text in Illustration
      *a

      Component without harness connected

      (Front Door Lock Assembly RH)

      *b Unlock
      *c Lock

      Check the detection switch (w/ Entry and Start System for LHD).


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        7 (LSSR) - 8 (E) Lock 10 kΩ or higher
        7 (LSSR) - 8 (E) Unlock Below 1 Ω

        If the result is not as specified, replace the front door lock assembly RH.

    3. A004IAWE03
      Text in Illustration
      *a

      Component without harness connected

      (Front Door Lock Assembly RH)

      *b Unlock
      *c Lock

      Check the detection switch (w/ Entry and Start System for RHD).


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        7 (LSSR) - 8 (E) Lock 10 kΩ or higher
        7 (LSSR) - 8 (E) Unlock Below 1 Ω

        If the result is not as specified, replace the front door lock assembly RH.

  4. INSPECT FRONT DOOR LOCK ASSEMBLY RH (w/ Double Locking System)

    A004KDGE10
    Text in Illustration
    *a

    Component without harness connected

    (Front Door Lock Assembly RH)

    *b Unlock
    *c Lock

    1. Check the operation of the door lock motor and double lock motor.


      1. Apply battery voltage to the door lock motor connector and check the operation of the door lock motor.

        OK
        Measurement Condition Specified Condition

        Battery positive (+) → 2 (L)

        Battery negative (-) → 1 (UL)

        Lock

        Battery positive (+) → 1 (UL)

        Battery negative (-) → 2 (L)

        Unlock

        Battery positive (+) → 4 (L)

        Battery negative (-) → 3 (UL)

        Set

        Battery positive (+) → 3 (UL)

        Battery negative (-) → 4 (L)

        Unset

        Tech Tips


        • Move the door lock motor to the lock position and set the double locking system. Check that the doors cannot be unlocked by operating the control cable.

        • Move the door lock motor to the lock position and unset the double locking system. Check that the doors can be unlocked by operating the control cable.

        If the result is not as specified, replace the front door lock assembly RH.

    2. A004HNFE02
      Text in Illustration
      *a

      Component without harness connected

      (Front Door Lock Assembly RH)

      *b Unlock
      *c Lock

      Check the detection switch (w/ Entry and Start System).


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        7 (LSSR) - 8 (E) Lock 10 kΩ or higher
        7 (LSSR) - 8 (E) Unlock Below 1 Ω

        If the result is not as specified, replace the front door lock assembly RH.

    3. A004HNVE05
      Text in Illustration
      *a

      Component without harness connected

      (Front Door Lock Assembly RH)

      *b Unlock
      *c Lock

      Check the door lock and unlock switch (w/ Key-linked Switch).


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        6 - 8 (E) Lock Below 1 Ω

        6 - 8 (E)

        5 - 8 (E)

        Off 10 kΩ or higher
        5 - 8 (E) Unlock Below 1 Ω

        If the result is not as specified, replace the front door lock assembly RH.