BACK-UP LIGHT SWITCH INSTALLATION

PROCEDURE


  1. INSTALL BACK-UP LIGHT SWITCH ASSEMBLY


    1. Using a 19 mm union nut wrench, install the back-up light switch assembly with a new gasket to the manual transmission assembly.

      Torque:
      32 N*m  { 329 kgf*cm, 24 ft.*lbf }

      Note

      Use the formula to calculate special torque values for situations where a union nut wrench is combined with a torque wrench Click here.

    2. A004IQSE01

      In the order indicated in the illustration, engage the 3 clamps in place, and connect the back-up light switch assembly wire and neutral position switch assembly wire.

      Tech Tips

      Install the wire harness so that there is slack on the connector side.

  2. INSTALL MANUAL TRANSMISSION ASSEMBLY

    Click here