RELAY ON-VEHICLE INSPECTION

PROCEDURE


  1. INSPECT ST RELAY


    1. A004JNZE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2

      Battery voltage not applied to terminals 1 and 2

      Measurement temperature : 20 °C

      93.8 to 136.4 kΩ
      3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
      Battery voltage applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the starter relay.

  2. REMOVE INHIBITOR RELAY


    1. A004JNZE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2

      Battery voltage not applied to terminals 1 and 2

      Measurement temperature : 20 °C

      93.8 to 136.4 kΩ
      3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
      Battery voltage applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the starter relay.

  3. INSPECT ST CUT RELAY


    1. A004KY3E02

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2

      Battery voltage not applied to terminals 1 and 2

      Measurement temperature : 20 °C

      93.8 to 136.4 kΩ
      3 - 4 Battery voltage not applied to terminals 1 and 2 Below 1 Ω
      Battery voltage applied to terminals 1 and 2 10 kΩ or higher
      3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
      Battery voltage applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the starter relay.

  4. INSPECT IGS RELAY


    1. A004JNZE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2

      Battery voltage not applied to terminals 1 and 2

      Measurement temperature : 20 °C

      93.8 to 136.4 kΩ
      3 - 5 Battery voltage not applied to terminals 1 and 2 10 kΩ or higher
      Battery voltage applied to terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the starter relay.