DESCRIPTION
When the stop light switch is turned on, current flows to the stop lights to illuminate them. During emergency braking, the brake control system blinks all stop lights to alert following drivers and reduces the possibility of a rear-end collision.
WIRING DIAGRAM
INSPECTION PROCEDURE
Note
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
CHECK FOR DTC (ELECTRONICALLY CONTROLLED BRAKE SYSTEM)
Check for DTCs Click here.
| OK |
|---|
| DTC output does not occur. |
| NG |
|
GO TO ELECTRONICALLY CONTROLLED BRAKE SYSTEM Click here |
| OK |
|
CHECK HARNESS AND CONNECTOR (NO. 2 INTEGRATION RELAY - BATTERY AND BODY GROUND)
| *a | Front view of wire harness connector (to No. 2 Integration Relay) |
Disconnect the No. 2 integration relay connectors.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||
|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (STOP LIGHT SWITCH - BATTERY AND BODY GROUND)
| *a | Front view of wire harness connector (to Stop Light Switch Assembly) |
Disconnect the stop light switch connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (STOP LIGHT SWITCH - NO. 2 INTEGRATION RELAY)
Disconnect the A5 stop light switch connector.
Disconnect the 1A No. 2 integration relay connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK STOP LIGHT SWITCH
| *a | Component with harness connected (Stop Light Switch Assembly) |
Disconnect the 1A No. 2 integration relay connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| Result | Proceed to |
|---|---|
| OK (Problem is that lights are flashing) | A |
| OK (Problem is that lights do not turn on or stay on) | B |
| NG | C |
| B |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| C |
|
REPLACE STOP LIGHT SWITCH ASSEMBLY Click here |
| A |
|
CHECK STOP LIGHT OPERATION
With the skid control ECU connector disconnected, check the illumination of the stop lights when depressing the brake pedal.
| OK |
|---|
| Stop lights operate normally when the brake pedal is depressed. |
| NG |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| OK |
|
REPLACE SKID CONTROL ECU ASSEMBLY Click here