BLIND SPOT MONITOR SYSTEM Power Source Circuit

DESCRIPTION

This circuit provides power to operate the blind spot monitor sensor.

WIRING DIAGRAM

A01FUQZE09

INSPECTION PROCEDURE

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH - BATTERY)


    1. A01FT7KE05
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Blind Spot Monitor Sensor RH)

      Disconnect connector from the blind spot monitor sensor RH.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      T39-5 (BRB) - Body ground Power switch on (IG) 11 to 14 V
      T39-5 (BRB) - Body ground Power switch off Below 1 V

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR RH - BODY GROUND)


    1. A01FT7KE04
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Blind Spot Monitor Sensor RH)

      Disconnect connector from the blind spot monitor sensor RH.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      T39-1 (BRGD) - Body ground Always Below 1 Ω

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - BATTERY)


    1. A01FT7KE07
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Blind Spot Monitor Sensor LH)

      Disconnect connector from the blind spot monitor sensor LH.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      U46-5 (BLB) - Body ground Power switch on (IG) 11 to 14 V
      U46-5 (BLB) - Body ground Power switch off Below 1 V

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (BLIND SPOT MONITOR SENSOR LH - BODY GROUND)


    1. A01FT7KE06
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Blind Spot Monitor Sensor LH)

      Disconnect connector from the blind spot monitor sensor LH.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      U46-1 (BLGD) - Body ground Always Below 1 Ω

    NG
    OK