DESCRIPTION
Blind spot monitor data and the Diagnostic Trouble Codes (DTCs) can be read from the Data Link Connector 3 (DLC3) of the vehicle. When the system seems to be malfunctioning, use the GTS to check for malfunctions and to repair it.
CHECK DLC3
Check the DLC3 Click here.
DIAGNOSIS FUNCTION
The blind spot monitor illuminates the blind spot monitor warning message on the combination meter assembly to inform the driver that the system is unavailable either temporarily, or unavailable due to a malfunction.
When the system is unavailable temporarily: Multi-information display displays "BSM not available".
When the system is unavailable due to a malfunction: Multi-information display displays "Check BSM System".
ABNORMALITY HISTORY
Tech Tips
The abnormality history for a blind spot monitor sensor can be displayed or cleared.
Check abnormality history
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Turn the blind spot monitor main switch (integration control and panel assembly) on.
Enter the following menus: Body Electrical / Blind Spot Monitor Master or Blind Spot Monitor Slave / Utility / BSM Master Abnormal History or BSM Slave Abnormal History
Check the results displayed for the abnormality history check.
Tech Tips
If "Yes" is displayed, check the suspected area column for each item.
Abnormality history is stored only for the blind spot monitor sensor for which an abnormality has been detected.
If "No" is displayed, proceed to the next suspected area shown in the Problem Symptoms Table Click here.
| Tester Display | Item Explanation | Suspected Area |
|---|---|---|
| History of Module Blockage | History of blind spot monitor sensor detection problems due to snow, rain etc. on the bumper |
|
| History of Low Voltage | History of low supply battery voltage from battery to the blind spot monitor sensor | Power source circuit Click here |
| History of High Voltage | History of high supply battery voltage from battery to the blind spot monitor sensor | |
| History of Low Temperature | History of low temperature for the blind spot monitor sensor | Check the outside temperature |
| History of High Temperature | History of high temperature for the blind spot monitor sensor |
Clear the malfunction history.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Turn the blind spot monitor main switch (integration control and panel assembly) on.
Enter the following menus: Body Electrical / Blind Spot Monitor Master or Blind Spot Monitor Slave / Utility / BSM Master Abnormal History or BSM Slave Abnormal History
Clear the BSM Master Abnormal History and/or BSM Slave Abnormal History.