AIR CONDITIONING SYSTEM ECO Switch Circuit

DESCRIPTION

When the combination switch is turned to ECO position, the air conditioning amplifier assembly controls the air conditioning system to enhance fuel efficiency.

WIRING DIAGRAM

A01FRP2E08

INSPECTION PROCEDURE

Note


  • When the auxiliary battery is disconnected or the air conditioning amplifier assembly is replaced, be sure to perform servo motor initialization Click here.

  • Before disconnecting the cable form the negative (-) battery terminal or replacing the air conditioning amplifier assembly, record the last operation state of the air conditioning for each transmitter. After replacement, it is necessary to perform memory registration for each transmitter Click here.

PROCEDURE


  1. READ VALUE USING GTS (ECO SWITCH)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Data List Click here.

    5. Check the values by referring to the table below.

      Air Conditioner
      Tester Display Measurement Item/Range Control Range Diagnostic Note
      ECO Switch

      Combination switch assembly /

      OFF or ON

      ON: Combination switch assembly being turned and held at ECO position

      OFF: Combination switch assembly not turned

      -
      OK
      The combination switch assembly condition displayed on the GTS changes with the actual switch operation.

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (COMBINATION SWITCH ASSEMBLY - AIR CONDITIONING AMPLIFIER ASSEMBLY AND BODY GROUND)


    1. Disconnect the N59 combination switch assembly connector.

    2. Disconnect the N78 air conditioning amplifier assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      N59-8 (ECU) - N78-29 (ECOS) Always Below 1 Ω
      N59-4 (GND) - Body ground Always Below 1 Ω
      N59-8 (ECU) - Body ground Always 10 kΩ or higher
      N59-8 (ECU) - N59-4 (GND) Always 10 kΩ or higher

    NG
    OK
  3. CHECK AIR CONDITIONING AMPLIFIER ASSEMBLY


    1. A01FPZ4E41
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Combination Switch Assembly)

      Reconnect the N78 air conditioning amplifier assembly connector.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      N59-8 (ECU) - Body ground Power switch off Below 1 V
      N59-8 (ECU) - Body ground Power switch on (IG) 11 to 14 V

    NG
    OK
  4. INSPECT COMBINATION SWITCH ASSEMBLY


    1. Remove the combination switch assembly Click here.

    2. Inspect the combination switch assembly Click here.


    NG
    OK