STEERING LINKAGE INSPECTION


  1. INSPECT TOTAL PRELOAD


    1. Temporarily install the left and right steering rack ends to prevent steering rack overstroke.

    2. A01FTIUE01

      Using SST and a torque wrench, inspect the preload.

      SST
      09616-00011
      Standard turning preload
      0.9 to 1.8 N*m (10 to 18 kgf*cm, 8 to 15 in.*lbf)

      If the turning torque is not as specified, replace the power steering link assembly.

  2. INSPECT POWER STEERING LINK ASSEMBLY


    1. Disconnect the power steering motor connector.

    2. A01FVQ5E01
      Text in Illustration
      *1 Power steering link assembly
      *a Area to set negative probe
      *b

      Component without harness connected

      (Power Steering Motor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (W) - 3 (U) Always 0.07 to 10 Ω
      2 (V) - 1 (W) Always 0.07 to 10 Ω
      3 (U) - 2 (V) Always 0.07 to 10 Ω
      1 (W) - Body ground* Always 100 kΩ or higher
      2 (V) - Body ground* Always 100 kΩ or higher
      3 (U) - Body ground* Always 100 kΩ or higher

      *: Touch the negative probe to the power steering link assembly housing at the position shown in the illustration to perform the measurement.

    3. Disconnect the torque sensor connector.

    4. A01FR5OE01
      Text in Illustration
      *a

      Component without harness connected

      (Torque Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (INCS) - 7 (TQG2) Always 90 to 170 Ω
      2 (INSN) - 7 (TQG2) Always 300 to 430 Ω
      4 (TRQV) - 8 (TQG1) Always 4 to 14 Ω
      5 (OUCS) - 7 (TQG2) Always 90 to 170 Ω
      6 (OUSN) - 7 (TQG2) Always 300 to 430 Ω
    5. Disconnect the motor rotation angle sensor connector.

    6. A01FUNHE01
      Text in Illustration
      *a

      Component without harness connected

      (Motor Rotation Angle Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 (RZSN) - 2 (RZG) Always 50 to 140 Ω
      3 (RZV) - 2 (RZG) Always 15 to 45 Ω
      4 (RZCS) - 2 (RZG) Always 50 to 140 Ω