BRAKE ACTUATOR INSPECTION


  1. CHECK BRAKE ACTUATOR ASSEMBLY


    1. for LHD:


      1. Measure the resistance according to the value(s) in the table below.

        A01FTNJE06
        Text in Illustration
        *a

        Component without harness connected

        (Brake Actuator Assembly)

        - -

        Tech Tips

        Check the brake actuator assembly when it is cooled down.

        Standard Resistance
        Tester Connection Condition Specified Condition
        20 (SMC1) - 19 (BS1) Always 15.3 to 25.0 Ω
        20 (SMC1) - Body ground Always 10 kΩ or higher
        6 (SMC2) - 7 (BS2) Always 15.3 to 25.0 Ω
        6 (SMC2) - Body ground Always 10 kΩ or higher
        8 (FRA+) - 5 (FRA-) Always 3.6 to 6.0 Ω
        8 (FRA+) - Body ground Always 10 kΩ or higher
        22 (FRR+) - 21 (FRR-) Always 3.6 to 6.0 Ω
        22 (FRR+) - Body ground Always 10 kΩ or higher
        13 (FLA+) - 14 (FLA-) Always 3.6 to 6.0 Ω
        13 (FLA+) - Body ground Always 10 kΩ or higher
        27 (FLR+) - 28 (FLR-) Always 3.6 to 6.0 Ω
        27 (FLR+) - Body ground Always 10 kΩ or higher
        12 (RRA+) - 11 (RRA-) Always 3.6 to 6.0 Ω
        12 (RRA+) - Body ground Always 10 kΩ or higher
        10 (RLA+) - 9 (RLA-) Always 3.6 to 6.0 Ω
        10 (RLA+) - Body ground Always 10 kΩ or higher
        26 (RRR+) - 25 (RRR-) Always 4.4 to 7.0 Ω
        26 (RRR+) - Body ground Always 10 kΩ or higher
        24 (RLR+) - 23 (RLR-) Always 4.4 to 7.0 Ω
        24 (RLR+) - Body ground Always 10 kΩ or higher

        If the result is not as specified, replace the brake actuator.

    2. for RHD:


      1. Measure the resistance according to the value(s) in the table below.

        A01FTNJE08
        Text in Illustration
        *a

        Component without harness connected

        (Brake Actuator Assembly)

        - -

        Tech Tips

        Check the brake actuator assembly when it is cooled down.

        Standard Resistance
        Tester Connection Condition Specified Condition
        37 (SMC1) - 36 (BS1) Always 15.3 to 25.0 Ω
        37 (SMC1) - Body ground Always 10 kΩ or higher
        19 (SMC2) - 20 (BS2) Always 15.3 to 25.0 Ω
        19 (SMC2) - Body ground Always 10 kΩ or higher
        44 (FRA+) - 43 (FRA-) Always 3.6 to 6.0 Ω
        44 (FRA+) - Body ground Always 10 kΩ or higher
        28 (FRR+) - 27 (FRR-) Always 3.6 to 6.0 Ω
        28 (FRR+) - Body ground Always 10 kΩ or higher
        35 (FLA+) - 38 (FLA-) Always 3.6 to 6.0 Ω
        35 (FLA+) - Body ground Always 10 kΩ or higher
        21 (FLR+) - 22 (FLR-) Always 3.6 to 6.0 Ω
        21 (FLR+) - Body ground Always 10 kΩ or higher
        39 (RRA+) - 40 (RRA-) Always 3.6 to 6.0 Ω
        39 (RRA+) - Body ground Always 10 kΩ or higher
        41 (RLA+) - 42 (RLA-) Always 3.6 to 6.0 Ω
        41 (RLA+) - Body ground Always 10 kΩ or higher
        23 (RRR+) - 24 (RRR-) Always 4.4 to 7.0 Ω
        23 (RRR+) - Body ground Always 10 kΩ or higher
        25 (RLR+) - 26 (RLR-) Always 4.4 to 7.0 Ω
        25 (RLR+) - Body ground Always 10 kΩ or higher

        If the result is not as specified, replace the brake actuator.

  2. CHECK BRAKE ACCUMULATOR PUMP


    1. for LHD:


      1. A01FVV3E01
        Text in Illustration
        *a

        Component without harness connected:

        (Brake Accumulator Pump)

        Measure the resistance according to the value(s) in the table below.

        Standard resistance
        Tester Connection Condition Specified Condition
        2 (BM1) - 31 (GND1) Always Below 1 Ω
        2 (BM1) - 32 (GND2) Always Below 1 Ω
        1 (BM2) - 31 (GND1) Always Below 1 Ω
        1 (BM2) - 32 (GND2) Always Below 1 Ω
        2 (BM1) - 33 (MTT) Always 450 to 550 Ω
        1 (BM2) - 33 (MTT) Always 450 to 550 Ω

        If the result is not as specified, replace the brake accumulator pump.

    2. for RHD:


      1. A01FVV3E02
        Text in Illustration
        *a

        Component without harness connected:

        (Brake Accumulator Pump)

        Measure the resistance according to the value(s) in the table below.

        Standard resistance
        Tester Connection Condition Specified Condition
        31 (BM1) - 1 (GND1) Always Below 1 Ω
        31 (BM1) - 2 (GND2) Always Below 1 Ω
        32 (BM2) - 1 (GND1) Always Below 1 Ω
        32 (BM2) - 2 (GND2) Always Below 1 Ω
        31 (BM1) - 3 (MTT) Always 450 to 550 Ω
        32 (BM2) - 3 (MTT) Always 450 to 550 Ω

        If the result is not as specified, replace the brake accumulator pump.