DATA LIST
Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Note
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Room Temperature Sensor | Cooler thermistor / min.: -6.50°C (20.30°F) max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | - |
| Ambient Temp Sensor | Thermistor assembly / Min: -23.30°C (-9.94°F) Max: 65.95°C (150.71°F) |
Actual ambient temperature displayed | - |
| Adjusted Ambient Temp | Adjusted ambient temperature / Min.: -30.80°C (-23.44°F) Max.: 50.80°C (123.44°F) |
- | - |
| Evaporator Fin Thermistor | No. 1 cooler thermistor / Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | - |
| Evaporator Target Temp | Evaporator target temperature / Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | - |
| Solar Sensor (D Side) | Driver side automatic light control sensor / Min.: 0, Max.: 255 |
Driver side automatic light control sensor value increases as brightness increases | - |
| Solar Sensor (P Side) | Front passenger side automatic light control sensor / Min.: 0, Max.: 255 |
Front passenger side automatic light control sensor value increases as brightness increases | - |
| Engine Coolant Temp | Engine coolant temperature sensor / Min.: 1.30°C (34.34°F) Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature displayed | - |
| Set Temperature (D Side) | Driver side set temperature / Min.: MAX COLD Max.: MAX HOT |
Driver side set temperature displayed | - |
| Set Temperature (P Side) | Passenger side set temperature / Min.: MAX COLD Max.: MAX HOT |
Passenger side set temperature displayed | - |
| Blower Motor Speed Level | Blower motor speed level / Min.: 0, Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower motor speed increases | - |
| Emission Gas Nox Sensor*6 | Smog ventilation sensor / Min.: 0, Max.: 255 |
Displays concentration of exhaust gas (NOx) around smog ventilation sensor (increases when concentration of exhaust gas increases) | - |
| Emission Gas Sensor*6 | Smog ventilation sensor / Min.: 0, Max.: 255 |
Displays concentration of exhaust gas (CO, HC) around smog ventilation sensor (increases when concentration of exhaust gas increases) | - |
| Regulator Pressure Sensor | Air conditioning pressure sensor / Min.: -456.68 kPa, Max.: 3294.37 kPa |
Actual pressure displayed | - |
| Set Temperature (Rear) | Rear set temperature / Min.: MAX COLD Max.: MAX HOT |
Actual rear set temperature displayed | - |
| Air Outlet Servo Pulse (R) | No. 7 air conditioning radiator damper servo sub-assembly target pulse / Min.: 128, Max.: 383 |
|
- |
| Air Outlet Servo Actual Pls(R) | No. 7 air conditioning radiator damper servo sub-assembly actual pulse / Min.: 128, Max.: 383 |
|
- |
| Air Mix Servo Targ Pulse(R) | No. 3 air conditioning radiator damper servo sub-assembly (rear side air mix) target pulse / Min.: 128, Max.: 383 |
MAX. COLD*2: 254 (pulse) MAX. HOT*3: 360 (pulse) |
- |
| Air Mix Servo Actual Pulse(R) | No. 3 air conditioning radiator damper servo sub-assembly (rear side air mix) actual pulse / Min.: 128, Max.: 383 |
MAX. COLD*2: 254 (pulse) MAX. HOT*3: 360 (pulse) |
- |
| Air Mix Servo Targ Pulse(D) | No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) target pulse / Min.: 128, Max.: 383 |
for RHD:
for LHD: |
- |
| Air Mix Servo Actual Pulse(D) | No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) actual pulse / Min.: 128, Max.: 383 |
for RHD:
for LHD: |
- |
| Air Mix Servo Targ Pulse(P) | No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) target pulse / Min.: 128, Max.: 383 |
for LHD:
for RHD: |
- |
| Air Mix Servo Actual Pulse(P) | No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) actual pulse / Min.: 128, Max.: 383 |
for LHD:
for RHD: |
- |
| Air Outlet Servo Pulse (D) | No. 6 air conditioning radiator damper servo sub-assembly target pulse*4 / Min.: 128, Max.: 383 |
|
- |
| No. 5 air conditioning radiator damper servo sub-assembly target pulse*5 / Min.: 128, Max.: 383 |
|
- | |
| Air Outlet Servo Actu Pulse(D) | No. 6 air conditioning radiator damper servo sub-assembly actual pulsez*4 / Min.: 128, Max.: 383 |
|
- |
| No. 5 air conditioning radiator damper servo sub-assembly actual pulse*5 / Min.: 128, Max.: 383 |
|
- | |
| Air Outlet Servo Targ Pulse(P) | No. 5 air conditioning radiator damper servo sub-assembly target pulse*4 / Min.: 128, Max.: 383 |
|
- |
| No. 6 air conditioning radiator damper servo sub-assembly target pulse*5 / Min.: 128, Max.: 383 |
|
- | |
| Air Outlet Servo Actu Pulse(P) | No. 5 air conditioning radiator damper servo sub-assembly actual pulse*4 / Min.: 128, Max.: 383 |
|
- |
| No. 6 air conditioning radiator damper servo sub-assembly actual pulse*5 / Min.: 128, Max.: 383 |
|
- | |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly target pulse / Min.: 128, Max.: 383 |
for LHD:
for RHD: |
- |
| Air Inlet Damper Actual Pulse | No. 1 blower damper servo sub-assembly actual pulse / Min.: 128, Max.: 383 |
for LHD:
for RHD: |
- |
| Electric Heater Count*1 | PTC heater Max. count / Min.: 0, Max.: 2 |
Max. number of the heater elements to be heated is displayed | - |
| Electric Heater Active Level*1 | PTC heater actual count / Min.: 0, Max.: 2 |
Actual number of the heater elements to be heated is displayed | - |
| Compressor Speed | Compressor with motor assembly speed / Min.: 0 rpm, Max.: 65535 rpm |
Actual compressor rotation speed displayed | - |
| Compressor Target Speed | Compressor with motor assembly target speed / Min.: 0 rpm, Max.: 65535 rpm |
Target compressor rotation speed displayed | - |
| Shift Set Temperature | Shift set temperature / 2C decr, 1C decr, Normal, 1C incr, 2C incr |
Customized value displayed | - |
| Air Inlet Mode | Air inlet mode / Auto or Manual |
Customized value displayed | - |
| Compressor Mode | Compressor mode / Auto or Manual |
Customized value displayed | - |
| Evaporator Control | Evaporator Control / Auto or Manual |
Customized value displayed | - |
| Emission Gas Sensor Shift*6 | Shift set smog ventilation sensor sensitivity / Normal, Mu More, Li More, Li Less, Less, Mu Less, More |
Customized value displayed | - |
| Add Foot Air in Face Mode | Add foot air in face mode / ON or OFF |
Customized value displayed | - |
| Noise and Vibration Reduction | Noise and vibration reduction / ON or OFF |
Customized value displayed | - |
| ECO MODE Cancel | ECO drive mode cancel / ON or OFF |
Customized value displayed | - |
| ECO Switch | Combination switch assembly / OFF or ON |
ON: Combination switch assembly being turned and held at ECO position OFF: Combination switch assembly not turned |
- |
| Refrigerant Shortage Check | Refrigerant shortage check / ON or OFF |
Customized value displayed | - |
| Fan speed increment control | Fan speed increment control / Slow, Normal, Fast |
Customized value displayed | - |
| Foot/DEF Auto Mode | Foot/DEF Auto Mode / ON or OFF |
Customized value displayed | - |
| Foot/DEF Auto Blow Up | Foot/DEF Auto blower speed increase / ON or OFF |
Customized value displayed | - |
| Ambient Temperature Shift | Ambient temperature shift / 3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr |
Customized value displayed | - |
| COOL A/M Servo Targ Pls(D) | No. 4 air conditioning radiator damper servo sub-assembly (driver side lower air mix) target pulse*4 / Min.: 128, Max.: 383 |
MAX. COLD*2: 254 (pulse) MAX. HOT*3: 360 (pulse) |
- |
| No. 3 air conditioning radiator damper servo sub-assembly (driver side lower air mix) target pulse*5 / Min.: 128, Max.: 383 |
MAX. COLD*2: 254 (pulse) MAX. HOT*3: 360 (pulse) |
- | |
| COOL A/M Servo Actual Pulse(D) | No. 4 air conditioning radiator damper servo sub-assembly (driver side lower air mix) actual pulse*4 / Min.: 128, Max.: 383 |
MAX. COLD*2: 254 (pulse) MAX. HOT*3: 360 (pulse) |
- |
| No. 3 air conditioning radiator damper servo sub-assembly (driver side lower air mix) target pulse*5 / Min.: 128, Max.: 383 |
MAX. COLD*2: 254 (pulse) MAX. HOT*3: 360 (pulse) |
- | |
| COOL A/M Servo Targ Pls(P) | No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) target pulse*4 / Min.: 128, Max.: 383 |
MAX. COLD*2: 254 (pulse) MAX. HOT*3: 360 (pulse) |
- |
| No. 4 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) actual pulse*5 / Min.: 128, Max.: 383 |
MAX. COLD*2: 254 (pulse) MAX. HOT*3: 360 (pulse) |
- | |
| COOL A/M Servo Actual Pulse(P) | No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) actual target pulse*4 / Min.: 128, Max.: 383 |
MAX. COLD*2: 254 (pulse) MAX. HOT*3: 360 (pulse) |
- |
| No. 4 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix) actual pulse*5 / Min.: 128, Max.: 383 |
MAX. COLD*2: 254 (pulse) MAX. HOT*3: 360 (pulse) |
- | |
| Pls Servo Test Sts | Pulse servo motor test status/ Wait, Move, Comp, Error, Stop |
Pulse servo motor test status | - |
| A/O Damper DEF Pos(D Side) | No. 1 air conditioning radiator damper servo sub-assembly target pulse / Min.: 128, Max.: 383 |
|
- |
| A/O Damper DEF Actual Pos(D) | No. 1 air conditioning radiator damper servo sub-assembly actual pulse / Min.: 128, Max.: 383 |
|
- |
| Compressor Drive Check | Compressor drive check / OK or NG |
OK: Compressor drives NG: Compressor does not drive |
- |
| Glass Temperature | Glass temperature/ Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Actual glass temperature displayed | - |
| Glass Surroundings Temperature | Glass surroundings temperature/ Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Actual glass surroundings temperature displayed | - |
| Glass Humidity | Glass humidity/ Min.: 0%, Max.: 100% |
Actual glass humidity displayed | - |
| Number of Trouble Codes | Number of trouble codes / Min.: 0, Max.: 255 |
Number of DTCs displayed | - |
*1: w/ PTC Heater
*2: Set temperature: LO
*3: Set temperature: HI
*4: for LHD
*5: for RHD
*6: w/ Smog Ventilation Sensor
ACTIVE TEST
Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower with fan motor sub-assembly | Min.: 0, Max.: 31 | - |
| Compressor Target Speed | Compressor with motor assembly | Min.: 0, Max.: 7500 | - |
| Heater Active Level*1 | Quick heater assembly | Min.: 0, Max.: 2 | - |
| Air Mix Servo Targ Pulse(D) | No. 2 air conditioning radiator damper servo sub-assembly (driver side upper air mix) | Min.: 128, Max.: 383 | Operates between 254 to 360 pulses*3 Operates between 152 to 258 pulses*4 |
| Air Mix Servo Targ Pulse(P) | No. 2 air conditioning radiator damper servo sub-assembly (front passenger side upper air mix) | Min.: 128, Max.: 383 | Operates between 152 to 258 pulses*3 Operates between 254 to 360 pulses*4 |
| Air Outlet Servo Pulse(D) | No. 6 air conditioning radiator damper servo sub-assembly*3 | Min.: 128, Max.: 383 | Operates between 140 to 254 pulses |
| No. 5 air conditioning radiator damper servo sub-assembly*4 | Min.: 128, Max.: 383 | Operates between 258 to 372 pulses | |
| Air Outlet Servo Pulse(P) | No. 5 air conditioning radiator damper servo sub-assembly*3 | Min.: 128, Max.: 383 | Operates between 258 to 372 pulses |
| No. 6 air conditioning radiator damper servo sub-assembly*4 | Min.: 128, Max.: 383 | Operates between 140 to 254 pulses | |
| Air Inlet Damper Targ Pulse | No. 1 blower damper servo sub-assembly | Min.: 128, Max.: 383 | Operates between 206 to 238 pulses*3 Operates between 274 to 306 pulses*4 |
| Cool A/M Servo Pulse(D) | No. 4 air conditioning radiator damper servo sub-assembly (driver side lower air mix)*3 | Min.: 128, Max.: 383 | Operates between 254 to 360 pulses |
| No. 3 air conditioning radiator damper servo sub-assembly (driver side lower air mix)*4 | Min.: 128, Max.: 383 | Operates between 254 to 360 pulses | |
| Cool A/M Servo Pulse(P) | No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix)*3 | Min.: 128, Max.: 383 | Operates between 254 to 360 pulses |
| No. 4 air conditioning radiator damper servo sub-assembly (front passenger side lower air mix)*4 | Min.: 128, Max.: 383 | Operates between 254 to 360 pulses | |
| A/O Servo Pulse(Rr D) | No. 7 air conditioning radiator damper servo sub-assembly | Min.: 128, Max.: 383 | Operates between 242 to 353 pulses |
| Rear Air Mix Servo Targ Pulse | No. 3 air conditioning radiator damper servo sub-assembly (rear side air mix) | Min.: 128, Max.: 383 | Operates between 254 to 360 pulses |
| DEF A/O Servo Pulse(D) | No. 1 air conditioning radiator damper servo sub-assembly | Min.: 128, Max.: 383 | Operates between 164 to 270 pulses |
| Ion Generator*2 | No. 1 ion generator sub-assembly | OFF/ON | - |
*1: w/ PTC Heater
*2: w/ Ion Generator
*3: for LHD
*4: for RHD