DESCRIPTION
The No. 1 cooler thermistor is installed on the evaporator in the air conditioner unit to detect the temperature of the air that has passed through the evaporator and is used to control the air conditioning. It sends signals to the air conditioning amplifier assembly. The resistance of the No. 1 cooler thermistor changes in accordance with the cooled air temperature that has passed through the evaporator. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.
The air conditioning amplifier assembly applies voltage (5 V) to the No. 1 cooler thermistor and reads voltage changes as the resistance of the No. 1 cooler thermistor changes. This sensor is used for frost prevention.
| DTC Code | DTC Detection Condition | Trouble Area |
|---|---|---|
| B1413/13 | Open or short in No. 1 cooler thermistor circuit |
|
WIRING DIAGRAM
INSPECTION PROCEDURE
Note
When the auxiliary battery is disconnected or the air conditioning amplifier assembly is replaced, be sure to perform servo motor initialization Click here.
Before disconnecting the cable form the negative (-) battery terminal or replacing the air conditioning amplifier assembly, record the last operation state of the air conditioning for each transmitter. After replacement, it is necessary to perform memory registration for each transmitter Click here.
PROCEDURE
READ VALUE USING GTS (EVAPORATOR FIN THERMISTOR)
Connect the GTS to the DLC3.
Turn the power switch on (IG).
Turn the GTS on.
Enter the following menus: Body Electrical / Air Conditioner / Data List Click here.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Evaporator Fin Thermistor | No. 1 cooler thermistor / Min.: -29.70°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | - |
| OK |
|---|
| The display is as specified in the normal condition column. |
| Result | Proceed to |
|---|---|
| NG | A |
| OK (When troubleshooting according to Problem Symptoms Table) | B |
| OK (When troubleshooting according to the DTC) | C |
| B |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| C |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here |
| A |
|
INSPECT NO. 1 COOLER THERMISTOR
Remove the No. 1 cooler thermistor Click here.
Inspect the No. 1 cooler thermistor Click here.
| NG |
|
REPLACE NO. 1 COOLER THERMISTOR Click here |
| OK |
|
INSPECT AIR CONDITIONING HARNESS ASSEMBLY
| *1 | Air Conditioning Harness Assembly |
| *a | Front view of wire harness connector (to Air Conditioning Amplifier Assembly) |
| *b | Front view of wire harness connector (to No. 1 cooler thermistor) |
Remove the air conditioning harness assembly Click here.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE AIR CONDITIONING HARNESS ASSEMBLY Click here |
| OK |
|
REPLACE AIR CONDITIONING AMPLIFIER ASSEMBLY Click here