HYBRID CONTROL SYSTEM, Diagnostic DTC:P2532-772

DTC Code DTC Name
P2532-772 Ignition Switch Run Position Circuit High

DESCRIPTION

The power source and HV CPU processors and their functions are integrated into the power management control ECU. The power source CPU and HV CPU use CAN communication to communicate with each other inside the power management control ECU. The power source CPU controls the opening and closing of the IG2 relay. The HV CPU detects that the IG2 relay is stuck ON (closed) based on relay operation information received from the power source CPU via CAN communication.

DTC No. INF Code DTC Detection Condition Trouble Area
P2532 772 Voltage is still applied to IG2 terminal even though an IG2 relay off command is received from the power source CPU.
  • Wire harness or connector

  • No. 1 integration relay (IG2 relay)

  • Power management control ECU

Tech Tips

If DTC P2532-772 is stored, the vehicle will turn off.

WIRING DIAGRAM

A01FQE9E01

INSPECTION PROCEDURE

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (+B SHORT)


    1. A01FQ69E27
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Disconnect the connector from the power management control ECU.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A36-1 (IG2) - Body ground Power switch off Below 1 V
      A36-2 (IG2D) - Body ground Power switch off Below 1 V
      Result
      Result Proceed to
      NG A
      OK B
    3. Connect the power management control ECU connector.


    B
    A
  2. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - IG2 RELAY)


    1. Disconnect the connector from the power management control ECU.

    2. A01FRTZE01
      Text in Illustration
      *1 No. 1 Engine Room Relay Block and Junction Block Assembly
      *2 No. 1 Integration Relay

      Remove the No. 1 integration relay from the No. 1 engine room relay block and junction block assembly.

    3. A01FQ69E27
      Text in Illustration
      *a

      Rear view of wire harness connector

      (to Power Management Control ECU)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      A36-1 (IG2) - Body ground Power switch off Below 1 V
      A36-2 (IG2D) - Body ground Power switch off Below 1 V
    4. Install the No. 1 integration relay.

    5. Connect the power management control ECU connector.


    NG
    OK