HYBRID CONTROL SYSTEM, Diagnostic DTC:P0A1A-200, P0A1A-792, P0A1A-793

DTC Code DTC Name
P0A1A-200 Generator Control Module
P0A1A-792 Generator Control Module
P0A1A-793 Generator Control Module

DESCRIPTION

The MG ECU located in the inverter with converter assembly monitors its internal operation and detects the following malfunctions.

DTC No. INF Code DTC Detection Condition Trouble Area
P0A1A 200 The difference between the resolver angle for control and estimated resolver angle exceeds the allowable value.
  • Inverter with converter assembly

  • Hybrid vehicle transmission assembly

  • Wire harness or connector

792 Resolver REF signal cycle error
793 Resolver REF signal oscillation stop error

WIRING DIAGRAM

A01FQDPE01

INSPECTION PROCEDURE

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the power switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

PROCEDURE


  1. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the power switch on (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      P0A1A-200, 792 or 793 only is output. A
      Any of the following DTCs are also output. B
      DTC No. Relevant Diagnosis
      P0A3F-243 Drive Motor "A" Position Sensor Circuit
      P0A4B-253 Generator Position Sensor Circuit
      P0A4C-513 Generator Position Sensor Circuit Range / Performance
      P0A4D-255 Generator Position Sensor Circuit Low
    5. Turn the power switch off.


    B
    A
  2. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly Click here.

      Note

      Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector cannot be pulled out.

      A01FRBVE01
      Text in Illustration
      *A for LHD *B for RHD
      OK
      The connectors are connected securely and there are no contact pressure problems.

      Tech Tips

      When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.


    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the connector from the inverter with converter assembly.

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the power switch on (IG).

    5. A01FQOWE17
      Text in Illustration
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-20 (GRF) - Body ground Power switch on (IG) Below 1 V
      A38-9 (GRFG) - Body ground Power switch on (IG) Below 1 V
      A38-18 (GSN) - Body ground Power switch on (IG) Below 1 V
      A38-7 (GSNG) - Body ground Power switch on (IG) Below 1 V
      A38-17 (GCS) - Body ground Power switch on (IG) Below 1 V
      A38-6 (GCSG) - Body ground Power switch on (IG) Below 1 V
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-20 (GRF) - Body ground Power switch on (IG) Below 1 V
      A74-9 (GRFG) - Body ground Power switch on (IG) Below 1 V
      A74-18 (GSN) - Body ground Power switch on (IG) Below 1 V
      A74-7 (GSNG) - Body ground Power switch on (IG) Below 1 V
      A74-17 (GCS) - Body ground Power switch on (IG) Below 1 V
      A74-6 (GCSG) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Turn the power switch off.

    7. Disconnect the cable from the negative (-) auxiliary battery terminal.

    8. Connect the inverter with converter assembly connector.


    NG
    OK
  4. CHECK GENERATOR RESOLVER

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the connector from the inverter with converter assembly.

    3. A01FQOWE17
      Text in Illustration
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-20 (GRF) - A38-9 (GRFG) Power switch off 4.2 to 12.5 Ω
      A38-18 (GSN) - A38-7 (GSNG) Power switch off 9.8 to 20.1 Ω
      A38-17 (GCS) - A38-6 (GCSG) Power switch off 9.8 to 20.1 Ω
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-20 (GRF) - A74-9 (GRFG) Power switch off 4.2 to 12.5 Ω
      A74-18 (GSN) - A74-7 (GSNG) Power switch off 9.8 to 20.1 Ω
      A74-17 (GCS) - A74-6 (GCSG) Power switch off 9.8 to 20.1 Ω
      Standard Resistance (Check for Short)
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-20 (GRF) or A38-9 (GRFG) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-18 (GSN) or A38-7 (GSNG) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-17 (GCS) or A38-6 (GCSG) - Body ground and other terminals Power switch off 10 kΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-20 (GRF) or A74-9 (GRFG) - Body ground and other terminals Power switch off 10 kΩ or higher
      A74-18 (GSN) or A74-7 (GSNG) - Body ground and other terminals Power switch off 10 kΩ or higher
      A74-17 (GCS) or A74-6 (GCSG) - Body ground and other terminals Power switch off 10 kΩ or higher
    4. Connect the inverter with converter assembly connector.


    NG
    OK
  5. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the connector from the inverter with converter assembly.

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the power switch on (IG).

    5. A01FQOWE18
      Text in Illustration
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-40 (MRF) - Body ground Power switch on (IG) Below 1 V
      A38-29 (MRFG) - Body ground Power switch on (IG) Below 1 V
      A38-39 (MSN) - Body ground Power switch on (IG) Below 1 V
      A38-28 (MSNG) - Body ground Power switch on (IG) Below 1 V
      A38-38 (MCS) - Body ground Power switch on (IG) Below 1 V
      A38-27 (MCSG) - Body ground Power switch on (IG) Below 1 V
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-40 (MRF) - Body ground Power switch on (IG) Below 1 V
      A74-29 (MRFG) - Body ground Power switch on (IG) Below 1 V
      A74-39 (MSN) - Body ground Power switch on (IG) Below 1 V
      A74-28 (MSNG) - Body ground Power switch on (IG) Below 1 V
      A74-38 (MCS) - Body ground Power switch on (IG) Below 1 V
      A74-27 (MCSG) - Body ground Power switch on (IG) Below 1 V

      Note

      Turning the power switch on (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Turn the power switch off.

    7. Disconnect the cable from the negative (-) auxiliary battery terminal.

    8. Connect the inverter with converter assembly connector.


    NG
    OK
  6. CHECK MOTOR RESOLVER

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the connector from the inverter with converter assembly.

    3. A01FQOWE18
      Text in Illustration
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-40 (MRF) - A38-29 (MRFG) Power switch off 4.2 to 12.5 Ω
      A38-39 (MSN) - A38-28 (MSNG) Power switch off 9.8 to 20.1 Ω
      A38-38 (MCS) - A38-27 (MCSG) Power switch off 9.8 to 20.1 Ω
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-40 (MRF) - A74-29 (MRFG) Power switch off 4.2 to 12.5 Ω
      A74-39 (MSN) - A74-28 (MSNG) Power switch off 9.8 to 20.1 Ω
      A74-38 (MCS) - A74-27 (MCSG) Power switch off 9.8 to 20.1 Ω
      Standard Resistance (Check for Short)
      for LHD
      Tester Connection Switch Condition Specified Condition
      A38-40 (MRF) or A38-29 (MRFG) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-39 (MSN) or A38-28 (MSNG) - Body ground and other terminals Power switch off 10 kΩ or higher
      A38-38 (MCS) or A38-27 (MCSG) - Body ground and other terminals Power switch off 10 kΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      A74-40 (MRF) or A74-29 (MRFG) - Body ground and other terminals Power switch off 10 kΩ or higher
      A74-39 (MSN) or A74-28 (MSNG) - Body ground and other terminals Power switch off 10 kΩ or higher
      A74-38 (MCS) or A74-27 (MCSG) - Body ground and other terminals Power switch off 10 kΩ or higher
    4. Connect the inverter with converter assembly connector.


    NG
    OK
  7. CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    1. A01FSLW

      Check the connection of the generator resolver connector Click here.

      OK
      The connector is connected securely and there are no contact problems.

    NG
    OK
  8. CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    1. A01FR9I

      Check the connection of the motor resolver connector Click here.

      OK
      The connector is connected securely and there are no contact problems.

    NG
    OK
  9. CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    1. A01FSLW

      Check the connection of the generator resolver connector Click here.

      OK
      The connector is connected securely and there are no contact problems.

    NG
    OK
  10. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the connector from the inverter with converter assembly.

    3. A01FT2DE03
      Text in Illustration
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Generator Resolver)

      *b

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Disconnect the generator resolver connector.

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      for LHD
      Tester Connection Switch Condition Specified Condition
      F50-1 (GRF) - A38-20 (GRF) Power switch off Below 1 Ω
      F50-5 (GRFG) - A38-9 (GRFG) Power switch off Below 1 Ω
      F50-2 (GSN) - A38-18 (GSN) Power switch off Below 1 Ω
      F50-6 (GSNG) - A38-7 (GSNG) Power switch off Below 1 Ω
      F50-3 (GCS) - A38-17 (GCS) Power switch off Below 1 Ω
      F50-7 (GCSG) - A38-6 (GCSG) Power switch off Below 1 Ω
      for RHD
      Tester Connection Switch Condition Specified Condition
      F50-1 (GRF) - A74-20 (GRF) Power switch off Below 1 Ω
      F50-5 (GRFG) - A74-9 (GRFG) Power switch off Below 1 Ω
      F50-2 (GSN) - A74-18 (GSN) Power switch off Below 1 Ω
      F50-6 (GSNG) - A74-7 (GSNG) Power switch off Below 1 Ω
      F50-3 (GCS) - A74-17 (GCS) Power switch off Below 1 Ω
      F50-7 (GCSG) - A74-6 (GCSG) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      for LHD
      Tester Connection Switch Condition Specified Condition
      F50-1 (GRF) or A38-20 (GRF) - Body ground and other terminals Power switch off 10 kΩ or higher
      F50-5 (GRFG) or A38-9 (GRFG) - Body ground and other terminals Power switch off 10 kΩ or higher
      F50-2 (GSN) or A38-18 (GSN) - Body ground and other terminals Power switch off 10 kΩ or higher
      F50-6 (GSNG) or A38-7 (GSNG) - Body ground and other terminals Power switch off 10 kΩ or higher
      F50-3 (GCS) or A38-17 (GCS) - Body ground and other terminals Power switch off 10 kΩ or higher
      F50-7 (GCSG) or A38-6 (GCSG) - Body ground and other terminals Power switch off 10 kΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      F50-1 (GRF) or A74-20 (GRF) - Body ground and other terminals Power switch off 10 kΩ or higher
      F50-5 (GRFG) or A74-9 (GRFG) - Body ground and other terminals Power switch off 10 kΩ or higher
      F50-2 (GSN) or A74-18 (GSN) - Body ground and other terminals Power switch off 10 kΩ or higher
      F50-6 (GSNG) or A74-7 (GSNG) - Body ground and other terminals Power switch off 10 kΩ or higher
      F50-3 (GCS) or A74-17 (GCS) - Body ground and other terminals Power switch off 10 kΩ or higher
      F50-7 (GCSG) or A74-6 (GCSG) - Body ground and other terminals Power switch off 10 kΩ or higher

      Tech Tips

      The generator resolver is not available separately. If it requires replacement, replace the hybrid vehicle transmission assembly.

    5. Connect the generator resolver connector.

    6. Connect the inverter with converter assembly connector.


    NG
    OK
  11. CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    1. A01FR9I

      Check the connection of the motor resolver connector Click here.

      OK
      The connector is connected securely and there are no contact problems.

    NG
    OK
  12. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the connector from the inverter with converter assembly.

    3. A01FT2DE04
      Text in Illustration
      *A for LHD
      *B for RHD
      *a

      Front view of wire harness connector

      (to Motor Resolver)

      *b

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Disconnect the motor resolver connector.

    4. Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      for LHD
      Tester Connection Switch Condition Specified Condition
      F51-1 (MRF) - A38-40 (MRF) Power switch off Below 1 Ω
      F51-5 (MRFG) - A38-29 (MRFG) Power switch off Below 1 Ω
      F51-2 (MSN) - A38-39 (MSN) Power switch off Below 1 Ω
      F51-6 (MSNG) - A38-28 (MSNG) Power switch off Below 1 Ω
      F51-3 (MCS) - A38-38 (MCS) Power switch off Below 1 Ω
      F51-7 (MCSG) - A38-27 (MCSG) Power switch off Below 1 Ω
      for RHD
      Tester Connection Switch Condition Specified Condition
      F51-1 (MRF) - A74-40 (MRF) Power switch off Below 1 Ω
      F51-5 (MRFG) - A74-29 (MRFG) Power switch off Below 1 Ω
      F51-2 (MSN) - A74-39 (MSN) Power switch off Below 1 Ω
      F51-6 (MSNG) - A74-28 (MSNG) Power switch off Below 1 Ω
      F51-3 (MCS) - A74-38 (MCS) Power switch off Below 1 Ω
      F51-7 (MCSG) - A74-27 (MCSG) Power switch off Below 1 Ω
      Standard Resistance (Check for Short)
      for LHD
      Tester Connection Switch Condition Specified Condition
      F51-1 (MRF) or A38-40 (MRF) - Body ground and other terminals Power switch off 10 kΩ or higher
      F51-5 (MRFG) or A38-29 (MRFG) - Body ground and other terminals Power switch off 10 kΩ or higher
      F51-2 (MSN) or A38-39 (MSN) - Body ground and other terminals Power switch off 10 kΩ or higher
      F51-6 (MSNG) or A38-28 (MSNG) - Body ground and other terminals Power switch off 10 kΩ or higher
      F51-3 (MCS) or A38-38 (MCS) - Body ground and other terminals Power switch off 10 kΩ or higher
      F51-7 (MCSG) or A38-27 (MCSG) - Body ground and other terminals Power switch off 10 kΩ or higher
      for RHD
      Tester Connection Switch Condition Specified Condition
      F51-1 (MRF) or A74-40 (MRF) - Body ground and other terminals Power switch off 10 kΩ or higher
      F51-5 (MRFG) or A74-29 (MRFG) - Body ground and other terminals Power switch off 10 kΩ or higher
      F51-2 (MSN) or A74-39 (MSN) - Body ground and other terminals Power switch off 10 kΩ or higher
      F51-6 (MSNG) or A74-28 (MSNG) - Body ground and other terminals Power switch off 10 kΩ or higher
      F51-3 (MCS) or A74-38 (MCS) - Body ground and other terminals Power switch off 10 kΩ or higher
      F51-7 (MCSG) or A74-27 (MCSG) - Body ground and other terminals Power switch off 10 kΩ or higher

      Tech Tips

      The motor resolver is not available separately. If it requires replacement, replace the hybrid vehicle transmission assembly.

    5. Connect the motor resolver connector.

    6. Connect the inverter with converter assembly connector.


    NG
    OK