RELAY ON-VEHICLE INSPECTION


  1. INSPECT IGNITION CONTROL RELAY (IGCT)


    1. A01FTILE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Auxiliary battery voltage is not applied across terminals 1 and 2 10 kΩ or higher
      3 - 5 Auxiliary battery voltage is applied across terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the relay.

  2. INSPECT HYBRID WATER PUMP RELAY (INV W/PMP)


    1. A01FSAGE01

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3 - 5 Auxiliary battery voltage is not applied across terminals 1 and 2 10 kΩ or higher
      3 - 5 Auxiliary battery voltage is applied across terminals 1 and 2 Below 1 Ω

      If the result is not as specified, replace the relay.