REMOVE ENGINE ROOM SIDE COVER
Remove the 4 clips and engine room side cover.
REMOVE COOL AIR INTAKE DUCT SEAL
Remove the 7 clips and cool air intake duct seal.
REMOVE NO. 1 AIR CLEANER INLET
Remove the bolt and No. 1 air cleaner inlet.
REMOVE AIR CLEANER CAP WITH NO. 2 AIR CLEANER HOSE
Disconnect the mass air flow meter sub-assembly connector.
Disconnect the wire harness clamp from the air cleaner cap with No. 2 air cleaner hose.
Detach the 4 clamps.
Loosen the hose clamp to remove the air cleaner cap with No. 2 air cleaner hose.
REMOVE AIR CLEANER FILTER ELEMENT SUB-ASSEMBLY
REMOVE AIR CLEANER CASE SUB-ASSEMBLY
| *a | Air Cleaner Support |
Disconnect the wire harness clamp from the air cleaner case sub-assembly.
Remove the 2 bolts and air cleaner case sub-assembly.
Note
Make sure the air cleaner support is attached to the vehicle body.
REMOVE ENGINE UNDER COVER
Remove the 13 screws, 3 clips and engine under cover.
DRAIN COOLANT (for Inverter)
Note
Do not reuse the drained coolant because it may contain foreign objects.
Collect the drained coolant and measure its volume to establish a benchmark. When adding coolant, make sure to add more coolant than the measured amount.
Remove the reservoir tank cap.
Loosen the drain cock plug.
CAUTION:
To avoid the danger of being burned, do not remove the reservoir tank cap while the coolant for the inverter is still hot.
REMOVE HV WATER PUMP BRACKET SUB-ASSEMBLY
Detach the inverter cooling hose clamp from the inverter water pump with motor assembly.
Slide the 2 clamps and disconnect the hybrid water pump inlet hose and No. 1 hybrid water pump outlet hose from the inverter water pump with motor assembly.
Note
Apply insulating tape to the pipe and in the disconnected hose or cover the pipe and hose with plastic bags to prevent entry of foreign matter.
Detach the 2 clamps and disconnect the inverter water pump connector.
Note
Wipe off any coolant from the connectors of the wire harness and inverter water pump with motor, and apply insulating tape to protect them from coolant.
Remove the 2 bolts and HV water pump bracket sub-assembly.
REMOVE INVERTER WATER PUMP WITH MOTOR ASSEMBLY
Remove the 3 bolts and inverter water pump with motor assembly from the HV water pump bracket sub-assembly.