RELAY ON-VEHICLE INSPECTION


  1. INSPECT NO. 1 INTEGRATION RELAY (EFI MAIN1)


    1. Inspect the EFI MAIN fuse.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        EFI MAIN fuse Always Below 1 Ω

        If the result is not as specified, replace the EFI MAIN fuse.

    2. Inspect the EFI No. 2 fuse.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        EFI No. 2 fuse Always Below 1 Ω

        If the result is not as specified, replace the EFI No. 2 fuse.

    3. Inspect the EFI MAIN1 relay.


      1. A01FTPZE03
        Text in Illustration
        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1D-1 - 1E-16 Battery voltage not applied to terminals 1E-6 and 1E-10 10 kΩ or higher
        Battery voltage applied to terminals 1E-6 and 1E-10 Below 1 Ω

        If the result is not as specified, replace the No. 1 integration relay.

  2. INSPECT NO. 1 INTEGRATION RELAY (EFI MAIN2)


    1. Inspect the F/PMP fuse.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        F/PMP fuse Always Below 1 Ω

        If the result is not as specified, replace the F/PMP fuse.

    2. Inspect the EFI MAIN2 relay.


      1. A01FTPZE02
        Text in Illustration
        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1D-1 - 1F-12 Battery voltage not applied to terminals 1F-10 and 1E-10 10 kΩ or higher
        Battery voltage applied to terminals 1F-10 and 1E-10 Below 1 Ω

        If the result is not as specified, replace the No. 1 integration relay.

  3. INSPECT NO. 1 INTEGRATION RELAY (INJ)


    1. Inspect the EDU fuse.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        EDU fuse Always Below 1 Ω

        If the result is not as specified, replace the EDU fuse.

    2. Inspect the INJ relay.


      1. A01FTPZE02
        Text in Illustration
        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1D-1 - 1F-11 Battery voltage not applied to terminals 1F-10 and 1E-19 10 kΩ or higher
        Battery voltage applied to terminals 1F-10 and 1E-19 Below 1 Ω

        If the result is not as specified, replace the No. 1 integration relay.

  4. INSPECT NO. 1 INTEGRATION RELAY (IG2)


    1. Inspect the IG2 MAIN fuse.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        IG2 MAIN fuse Always Below 1 Ω

        If the result is not as specified, replace the IG2 MAIN fuse.

    2. Inspect the IG2 relay.


      1. A01FTPZE02
        Text in Illustration
        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1D-1 - 1F-2 Battery voltage not applied to terminals 1E-2 and 1E-10 10 kΩ or higher
        Battery voltage applied to terminals 1E-2 and 1E-10 Below 1 Ω

        If the result is not as specified, replace the No. 1 integration relay.

  5. INSPECT NO. 1 INTEGRATION RELAY (A/F)


    1. Inspect the A/F fuse.


      1. Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        A/F fuse Always Below 1 Ω

        If the result is not as specified, replace the A/F fuse.

    2. Inspect the A/F relay.


      1. A01FTPZE02
        Text in Illustration
        *a

        Component without harness connected

        (No. 1 Integration Relay)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Condition Specified Condition
        1D-1 - 1F-4 Battery voltage not applied to terminals 1E-16 and 1E-10 10 kΩ or higher
        Battery voltage applied to terminals 1E-16 and 1E-10 Below 1 Ω

        If the result is not as specified, replace the No. 1 integration relay.