RELAY ON-VEHICLE INSPECTION


  1. INSPECT OIL PUMP RELAY


    1. Disconnect wore harness Click here.

    2. A01FTJLE04

      Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection Specified Condition
      3-5 10 MΩ or higher
      3-5 Below 1 Ω (when battery voltage is applied to terminals 1 and 2)

      If the result is not as specified, replace the relay.

    3. Connect wire harness Click here.