AIR CONDITIONING SYSTEM DATA LIST / ACTIVE TEST


  1. DATA LIST

    Using the GTS to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.

    Note

    In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.


    1. Connect the GTS to the DLC3.

    2. Turn the engine switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    5. Check the value(s) by referring to the table below.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Room Temperature Sensor

      Cooler thermistor /

      Min.: -6.50°C (20.30°F)

      Max.: 57.25°C (135.05°F)

      Actual cabin temperature displayed -
      Ambient Temp Sensor

      Thermistor assembly /

      Min: -23.30°C (-9.94°F)

      Max: 65.95°C (150.71°F)

      Actual ambient temperature displayed -
      Adjusted Ambient Temp

      Adjusted ambient temperature /

      Min.: -30.80°C (-23.44°F)

      Max.: 50.80°C (123.44°F)

      - -
      Evaporator Fin Thermistor

      No. 1 cooler thermistor /

      Min.: -29.70°C (-21.46°F)

      Max.: 59.55°C (139.19°F)

      Actual evaporator temperature displayed -
      Evaporator Target Temp

      Evaporator target temperature /

      Min.: -327.68°C (-557.82°F)

      Max.: 327.67°C (621.81°F)

      Evaporator target temperature displayed -
      Solar Sensor (D Side)

      Driver side automatic light control sensor /

      Min.: 0, Max.: 255

      Driver side automatic light control sensor value increases as brightness increases -
      Solar Sensor (P Side)

      Front passenger side automatic light control sensor /

      Min.: 0, Max.: 255

      Front passenger side automatic light control sensor value increases as brightness increases -
      Engine Coolant Temp

      Engine coolant temperature sensor /

      Min.: 1.30°C (34.34°F)

      Max.: 90.55°C (194.99°F)

      Actual engine coolant temperature displayed -
      Set Temperature (D Side)

      Driver side set temperature /

      Min.: MAX COLD

      Max.: MAX HOT

      Driver side set temperature displayed -
      Set Temperature (P Side)

      Passenger side set temperature /

      Min.: MAX COLD

      Max.: MAX HOT

      Passenger side set temperature displayed -
      Blower Motor Speed Level

      Blower motor speed level /

      Min.: 0, Max.: 31

      Displayed speed level increases in range between 0 and 31 as blower motor speed increases -
      Emission Gas Nox Sensor*5

      Smog ventilation sensor /

      Min.: 0, Max.: 255

      Displays concentration of exhaust gas (NOx) around smog ventilation sensor (increases when concentration of exhaust gas increases) -
      Emission Gas Sensor*5

      Smog ventilation sensor /

      Min.: 0, Max.: 255

      Displays concentration of exhaust gas (CO, HC) around smog ventilation sensor (increases when concentration of exhaust gas increases) -
      Regulator Pressure Sensor

      Air conditioning pressure sensor /

      Min.: -456.68 kPa,

      Max.: 3294.37 kPa

      Actual pressure displayed -
      Regular Control Current

      Solenoid valve control current /

      Min.: 0 A, Max.: 0.997 A

      Value Changes between 0 A and 0.997 A in accordance with solenoid valve operation -
      Set Temperature (Rear)*1

      Rear set temperature /

      Min.: MAX COLD

      Max.: MAX HOT

      Actual rear set temperature displayed -
      Air Outlet Servo Pulse (R)

      No. 7 air conditioning radiator damper servo sub-assembly target pulse /

      Min.: 128, Max.: 383


      • FACE1: 245 (pulse)

      • FACE2: 242 (pulse)

      • FACE: 242 (pulse)

      • B/L1: 284 (pulse)

      • B/L: 284 (pulse)

      • B/L2: 303 (pulse)

      • FOOT: 303 (pulse)

      • FOOT/DEF: 333 (pulse)

      • DEF: 353 (pulse)

      -
      Air Outlet Servo Actual Pls(R)

      No. 7 air conditioning radiator damper servo sub-assembly actual pulse /

      Min.: 128, Max.: 383


      • FACE1: 245 (pulse)

      • FACE2: 242 (pulse)

      • FACE: 242 (pulse)

      • B/L1: 284 (pulse)

      • B/L: 284 (pulse)

      • B/L2: 303 (pulse)

      • FOOT: 303 (pulse)

      • FOOT/DEF: 333 (pulse)

      • DEF: 353 (pulse)

      -
      Air Mix Servo Targ Pulse(R)*1

      No. 3 air conditioning radiator damper servo sub-assembly (rear air mix) target pulse /

      Min.: 128, Max.: 383

      MAX COLD*3: 254 (pulse)

      MAX HOT*4: 360 (pulse)

      -
      Air Mix Servo Actual Pulse(R)*1

      No. 3 air conditioning radiator damper servo sub-assembly (rear air mix) actual pulse /

      Min.: 128, Max.: 383

      MAX COLD*3: 254 (pulse)

      MAX HOT*4: 360 (pulse)

      -
      Air Mix Servo Targ Pulse(D)

      No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix) target pulse /

      Min.: 128, Max.: 383


        for RHD:

      • MAX COLD*3: 254 (pulse)

      • MAX HOT*4: 360 (pulse)


        for LHD:

      • MAX COLD*3: 258 (pulse)

      • MAX HOT*4: 152 (pulse)

      -
      Air Mix Servo Actual Pulse(D)

      No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix) actual pulse /

      Min.: 128, Max.: 383


        for LHD:

      • MAX COLD*3: 254 (pulse)

      • MAX HOT*4: 360 (pulse)


        for RHD:

      • MAX COLD*3: 258 (pulse)

      • MAX HOT*4: 152 (pulse)

      -
      Air Mix Servo Targ Pulse(P)

      No. 2 air conditioning radiator damper servo sub-assembly (front passenger side air mix) target pulse /

      Min.: 128, Max.: 383


        for LHD:

      • MAX COLD*3: 258 (pulse)

      • MAX HOT*4: 152 (pulse)


        for RHD:

      • MAX COLD*3: 254 (pulse)

      • MAX HOT*4: 360 (pulse)

      -
      Air Mix Servo Actual Pulse(P)

      No. 2 air conditioning radiator damper servo sub-assembly (front passenger side air mix) actual pulse /

      Min.: 128, Max.: 383


        for LHD:

      • MAX COLD*3: 258 (pulse)

      • MAX HOT*4: 152 (pulse)


        for RHD:

      • MAX COLD*3: 254 (pulse)

      • MAX HOT*4: 360 (pulse)

      -
      Air Outlet Servo Pulse (D)

      No. 6 air conditioning radiator damper servo sub-assembly target pulse*8 /

      Min.: 128, Max.: 383


      • FACE1: 254 (pulse)

      • FACE2: 245 (pulse)

      • FACE: 230 (pulse)

      • B/L: 217 (pulse)

      • B/L2: 209 (pulse)

      • FOOT-0 (for save energy and airflow control function): 183 (pulse)

      • FOOT-0 (except save energy and airflow control function): 199 (pulse)

      • FOOT-D: 199 (pulse)

      • FOOT-R (for save energy and airflow control function): 183 (pulse)

      • FOOT-R (except save energy and airflow control function): 191 to 199 (pulse)

      • FOOT-F (manual mode and for save energy and airflow control function): 183 (pulse)

      • FOOT-F (manual mode and except save energy and airflow control function): 199 (pulse)

      • FOOT-F (automatic mode): 183 (pulse)

      • FOOT/DEF: 168 (pulse)

      • DEF: 140 (pulse)

      -

      No. 5 air conditioning radiator damper servo sub-assembly target pulse*9 /

      Min.: 128, Max.: 383


      • FACE1: 258 (pulse)

      • FACE2: 267 (pulse)

      • FACE: 282 (pulse)

      • B/L: 295 (pulse)

      • B/L2: 303 (pulse)

      • FOOT-0 (for save energy and airflow control function): 329 (pulse)

      • FOOT-0 (except save energy and airflow control function): 313 (pulse)

      • FOOT-D: 313 (pulse)

      • FOOT-R (for save energy and airflow control function): 329 (pulse)

      • FOOT-R (except save energy and airflow control function): 313 to 321 (pulse)

      • FOOT-F (manual mode and for save energy and airflow control function): 329 (pulse)

      • FOOT-F (manual mode and except save energy and airflow control function): 313 (pulse)

      • FOOT-F (automatic mode): 329 (pulse)

      • FOOT/DEF: 344 (pulse)

      • DEF: 372 (pulse)

      -
      Air Outlet Servo Actu Pulse(D)

      No. 6 air conditioning radiator damper servo sub-assembly actual pulse*8 /

      Min.: 128, Max.: 383


      • FACE1: 254 (pulse)

      • FACE2: 245 (pulse)

      • FACE: 230 (pulse)

      • B/L: 217 (pulse)

      • B/L2: 209 (pulse)

      • FOOT-0 (for save energy and airflow control function): 183 (pulse)

      • FOOT-0 (except save energy and airflow control function): 199 (pulse)

      • FOOT-D: 199 (pulse)

      • FOOT-R (for save energy and airflow control function): 183 (pulse)

      • FOOT-R (except save energy and airflow control function): 191 to 199 (pulse)

      • FOOT-F (manual mode and for save energy and airflow control function): 183 (pulse)

      • FOOT-F (manual mode and except save energy and airflow control function): 199 (pulse)

      • FOOT-F (automatic mode): 183 (pulse)

      • FOOT/DEF: 168 (pulse)

      • DEF: 140 (pulse)

      -

      No. 5 air conditioning radiator damper servo sub-assembly actual pulse*9 /

      Min.: 128, Max.: 383


      • FACE1: 258 (pulse)

      • FACE2: 267 (pulse)

      • FACE: 282 (pulse)

      • B/L: 295 (pulse)

      • B/L2: 303 (pulse)

      • FOOT-0 (for save energy and airflow control function): 329 (pulse)

      • FOOT-0 (except save energy and airflow control function): 313 (pulse)

      • FOOT-D: 313 (pulse)

      • FOOT-R (for save energy and airflow control function): 329 (pulse)

      • FOOT-R (except save energy and airflow control function): 313 to 321 (pulse)

      • FOOT-F (manual mode and for save energy and airflow control function): 329 (pulse)

      • FOOT-F (manual mode and except save energy and airflow control function): 313 (pulse)

      • FOOT-F (automatic mode): 329 (pulse)

      • FOOT/DEF: 344 (pulse)

      • DEF: 372 (pulse)

      -
      Air Outlet Servo Targ Pulse(P)

      No. 5 air conditioning radiator damper servo sub-assembly target pulse*10 /

      Min.: 128, Max.: 383


      • FACE1: 258 (pulse)

      • FACE2: 267 (pulse)

      • FACE: 282 (pulse)

      • B/L: 295 (pulse)

      • B/L2: 303 (pulse)

      • FOOT-0 (for save energy and airflow control function): 329 (pulse)

      • FOOT-0 (except save energy and airflow control function): 313 (pulse)

      • FOOT-D: 313 (pulse)

      • FOOT-R (for save energy and airflow control function): 329 (pulse)

      • FOOT-R (except save energy and airflow control function): 313 to 321 (pulse)

      • FOOT-F (manual mode and for save energy and airflow control function): 329 (pulse)

      • FOOT-F (manual mode and except save energy and airflow control function): 313 (pulse)

      • FOOT-F (automatic mode): 329 (pulse)

      • FOOT/DEF: 344 (pulse)

      • DEF: 372 (pulse)

      -

      No. 6 air conditioning radiator damper servo sub-assembly target pulse*9 /

      Min.: 128, Max.: 383


      • FACE1: 254 (pulse)

      • FACE2: 245 (pulse)

      • FACE: 230 (pulse)

      • B/L: 217 (pulse)

      • B/L2: 209 (pulse)

      • FOOT-0 (for save energy and airflow control function): 183 (pulse)

      • FOOT-0 (except save energy and airflow control function): 199 (pulse)

      • FOOT-D: 199 (pulse)

      • FOOT-R (for save energy and airflow control function): 183 (pulse)

      • FOOT-R (except save energy and airflow control function): 191 to 199 (pulse)

      • FOOT-F (manual mode and for save energy and airflow control function): 183 (pulse)

      • FOOT-F (manual mode and except save energy and airflow control function): 199 (pulse)

      • FOOT-F (automatic mode): 183 (pulse)

      • FOOT/DEF: 168 (pulse)

      • DEF: 140 (pulse)

      Air Outlet Servo Actu Pulse(P)

      No. 5 air conditioning radiator damper servo sub-assembly actual pulse*10 /

      Min.: 128, Max.: 383


      • FACE1: 258 (pulse)

      • FACE2: 267 (pulse)

      • FACE: 282 (pulse)

      • B/L: 295 (pulse)

      • B/L2: 303 (pulse)

      • FOOT-0 (for save energy and airflow control function): 329 (pulse)

      • FOOT-0 (except save energy and airflow control function): 313 (pulse)

      • FOOT-D: 313 (pulse)

      • FOOT-R (for save energy and airflow control function): 329 (pulse)

      • FOOT-R (except save energy and airflow control function): 313 to 321 (pulse)

      • FOOT-F (manual mode and for save energy and airflow control function): 329 (pulse)

      • FOOT-F (manual mode and except save energy and airflow control function): 313 (pulse)

      • FOOT-F (automatic mode): 329 (pulse)

      • FOOT/DEF: 344 (pulse)

      • DEF: 372 (pulse)

      -

      No. 6 air conditioning radiator damper servo sub-assembly actual pulse*9 /

      Min.: 128, Max.: 383


      • FACE1: 254 (pulse)

      • FACE2: 245 (pulse)

      • FACE: 230 (pulse)

      • B/L: 217 (pulse)

      • B/L2: 209 (pulse)

      • FOOT-0 (for save energy and airflow control function): 183 (pulse)

      • FOOT-0 (except save energy and airflow control function): 199 (pulse)

      • FOOT-D: 199 (pulse)

      • FOOT-R (for save energy and airflow control function): 183 (pulse)

      • FOOT-R (except save energy and airflow control function): 191 to 199 (pulse)

      • FOOT-F (manual mode and for save energy and airflow control function): 183 (pulse)

      • FOOT-F (manual mode and except save energy and airflow control function): 199 (pulse)

      • FOOT-F (automatic mode): 183 (pulse)

      • FOOT/DEF: 168 (pulse)

      • DEF: 140 (pulse)

      -
      Air Inlet Damper Targ Pulse

      No. 1 blower damper servo sub-assembly target pulse /

      Min.: 128, Max.: 383


        for LHD:

      • FRESH: 206 (pulse)

      • RECIRCULATION: 238 (pulse)


        for RHD:

      • FRESH: 306 (pulse)

      • RECIRCULATION: 274 (pulse)

      -
      Air Inlet Damper Actual Pulse

      No. 1 blower damper servo sub-assembly actual pulse /

      Min.: 128, Max.: 383


        for LHD:

      • FRESH: 206 (pulse)

      • RECIRCULATION: 238 (pulse)


        for RHD:

      • FRESH: 306 (pulse)

      • RECIRCULATION: 274 (pulse)

      -
      Electric Heater Count*2

      PTC heater Max. count /

      Min.: 0, Max.: 2

      Max. number of the heater elements to be heated is displayed -
      Electric Heater Active Level*2

      PTC heater actual count /

      Min.: 0, Max.: 2

      Actual number of the heater elements to be heated is displayed -
      Shift Set Temperature

      Shift set temperature /

      2C decr, 1C decr, Normal, 1C incr, 2C incr

      Customized value displayed -
      Air Inlet Mode

      Air inlet mode /

      Auto or Manual

      Customized value displayed -
      Compressor Mode

      Compressor mode /

      Auto or Manual

      Customized value displayed -
      Evaporator Control

      Evaporator Control /

      Auto or Manual

      Customized value displayed -
      Emission Gas Sensor Shift*5

      Shift set smog ventilation sensor sensitivity /

      Normal, Mu More, Li More, Li Less, Less, Mu Less, More

      Customized value displayed -
      Add Foot Air in Face Mode

      Add foot air in face mode /

      ON or OFF

      Customized value displayed -
      ECO MODE Cancel

      ECO drive mode cancel /

      ON or OFF

      Customized value displayed -
      ECO Switch

      Combination switch assembly /

      OFF or ON

      ON: Combination switch assembly being turned and held at ECO position

      OFF: Combination switch assembly not turned

      -
      Refrigerant Shortage Check

      Refrigerant shortage check /

      ON or OFF

      Customized value displayed -
      Fan speed increment control

      Fan speed increment control /

      Slow, Normal, Fast

      Customized value displayed -
      Foot/DEF Auto Mode

      Foot/DEF Auto Mode /

      ON or OFF

      Customized value displayed -
      Foot/DEF Auto Blow Up

      Foot/DEF Auto blower speed increase /

      ON or OFF

      Customized value displayed -
      Ambient Temperature Shift

      Ambient temperature shift /

      3C decr, 2C decr, 1C decr, Normal, 1C incr, 2C incr, 3C incr

      Customized value displayed -
      COOL A/M Servo Targ Pls(D)

      No. 4 air conditioning radiator damper servo sub-assembly target pulse*6 /

      Min.: 128, Max.: 383

      MAX COLD*3: 254 (pulse)

      MAX HOT*4: 360 (pulse)

      -

      No. 3 air conditioning radiator damper servo sub-assembly (driver side lower) target pulse*7 /

      Min.: 128, Max.: 383

      MAX COLD*3: 254 (pulse)

      MAX HOT*4: 360 (pulse)

      -
      COOL A/M Servo Actual Pulse(D)

      No. 4 air conditioning radiator damper servo sub-assembly actual pulse*6 /

      Min.: 128, Max.: 383

      MAX COLD*3: 254 (pulse)

      MAX HOT*4: 360 (pulse)

      -

      No. 3 air conditioning radiator damper servo sub-assembly (driver side lower) actual pulse*7 /

      Min.: 128, Max.: 383

      MAX COLD*3: 254 (pulse)

      MAX HOT*4: 360 (pulse)

      -
      COOL A/M Servo Targ Pls(P)

      No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower) target pulse*6 /

      Min.: 128, Max.: 383

      MAX COLD*3: 254 (pulse)

      MAX HOT*4: 360 (pulse)

      -

      No. 4 air conditioning radiator damper servo sub-assembly target pulse*7 /

      Min.: 128, Max.: 383

      MAX COLD*3: 254 (pulse)

      MAX HOT*4: 360 (pulse)

      -
      COOL A/M Servo Actual Pulse(P)

      No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower) actual target pulse*6 /

      Min.: 128, Max.: 383

      MAX COLD*3: 254 (pulse)

      MAX HOT*4: 360 (pulse)

      -

      No. 4 air conditioning radiator damper servo sub-assembly actual target pulse*7 /

      Min.: 128, Max.: 383

      MAX COLD*3: 254 (pulse)

      MAX HOT*4: 360 (pulse)

      -
      Pls Servo Test Sts

      Pulse servo motor test status/

      Wait, Move, Comp, Error, Stop

      Pulse servo motor test status -
      Flow Sensor

      Flow sensor /

      Min.: 0 V, Max.: 5 V

      Value changes between 0.3 V to 4.7 V in accordance with flow sensor condition
      • Check this item with the engine idling, Blower switch LO level and A/C switch on.

      • The flow sensor is malfunctioning when a constant value below 0.3 V or higher than 4.7 V is displayed continuously for more than 4 seconds.

      A/O Damper DEF Pos(D Side)

      No. 1 air conditioning radiator damper servo sub-assembly target pulse /

      Min.: 128, Max.: 383


      • FACE1: 164 (pulse)

      • FACE2: 164 (pulse)

      • FACE: 164 (pulse)

      • B/L (manual mode): 164 (pulse)

      • B/L (automatic mode): 164 to 180 (pulse)

      • B/L2: 164 (pulse)

      • FOOT-0: 164 (pulse)

      • FOOT-D: 180 (pulse)

      • FOOT-R: 176 (pulse)

      • FOOT (manual mode): 176 (pulse)

      • FOOT (automatic mode): 176 to 186 (pulse)

      • FOOT/DEF: 270 (pulse)

      • DEF: 270 (pulse)

      -
      A/O Damper DEF Actual Pos(D)

      No. 1 air conditioning radiator damper servo sub-assembly actual pulse /

      Min.: 128, Max.: 383


      • FACE1: 164 (pulse)

      • FACE2: 164 (pulse)

      • FACE: 164 (pulse)

      • B/L (manual mode): 164 (pulse)

      • B/L (automatic mode): 164 to 180 (pulse)

      • B/L2: 164 (pulse)

      • FOOT-0: 164 (pulse)

      • FOOT-D: 180 (pulse)

      • FOOT-R: 176 (pulse)

      • FOOT (manual mode): 176 (pulse)

      • FOOT (automatic mode): 176 to 186 (pulse)

      • FOOT/DEF: 270 (pulse)

      • DEF: 270 (pulse)

      -
      A/C Cutoff Signal

      Air conditioning control cutoff signal /

      OFF or ON

      OFF: Air conditioning control permitted

      ON: Air conditioning control not permitted

      -
      Glass Temperature

      Glass temperature/

      Min.: -327.68°C (-557.82°F)

      Max.: 327.67°C (621.81°F)

      Actual glass temperature displayed -
      Glass Surroundings Temperature

      Glass surroundings temperature/

      Min.: -327.68°C (-557.82°F)

      Max.: 327.67°C (621.81°F)

      Actual glass surroundings temperature displayed -
      Glass Humidity

      Glass humidity/

      Min.: 0%, Max.: 100%

      Actual glass humidity displayed -
      Number of Trouble Codes

      Number of trouble codes /

      Min.: 0, Max.: 255

      Number of DTCs displayed -

      • *1: w/ Rear Control Switch

      • *2: w/ PTC Heater

      • *3: Set temperature: LO

      • *4: Set temperature: HI

      • *5: w/ Smog Ventilation Sensor

      • *6: for LHD

      • *7: for RHD

      • *8: for LHD or RHD without Rear Control Switch

      • *9: for RHD with Rear Control Switch

      • *10: for LHD with Rear Control Switch

  2. ACTIVE TEST

    Using the GTS to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.


    1. Connect the GTS to the DLC3.

    2. Turn the engine switch on (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Active Test.

    5. Check the operation by referring to the table below.

      Air Conditioner
      Tester Display Test Part Control Range Diagnostic Note
      Blower Motor Blower with fan motor sub-assembly Min.: 0, Max.: 31 -
      Magnetic Clutch Relay Cooler compressor assembly OFF, ON -
      Heater Active Level*1 Quick Heater Assembly Min.: 0, Max.: 2 -
      Air Mix Servo Targ Pulse(D) No. 2 air conditioning radiator damper servo sub-assembly (driver side air mix) Min.: 128, Max.: 383

      Operates between 254 to 360 pulses*3

      Operates between 152 to 258 pulses*4

      Air Mix Servo Targ Pulse(P) No. 2 air conditioning radiator damper servo sub-assembly (front passenger side air mix) Min.: 128, Max.: 383

      Operates between 152 to 258 pulses*3

      Operates between 254 to 360 pulses*4

      Air Outlet Servo Pulse(D) No. 6 air conditioning radiator damper servo sub-assembly*5 Min.: 128, Max.: 383 Operates between 140 to 254 pulses
      No. 5 air conditioning radiator damper servo sub-assembly*6 Min.: 128, Max.: 383 Operates between 258 to 372 pulses
      Air Outlet Servo Pulse(P) No. 5 air conditioning radiator damper servo sub-assembly*7 Min.: 128, Max.: 383 Operates between 258 to 372 pulses
      No. 6 air conditioning radiator damper servo sub-assembly*6 Min.: 128, Max.: 383 Operates between 140 to 254 pulses
      Air Inlet Damper Targ Pulse No. 1 blower damper servo sub-assembly Min.: 128, Max.: 383

      Operates between 206 to 238 pulses*3

      Operates between 274 to 306 pulses*4

      Cool A/M Servo Pulse(D) No. 4 air conditioning radiator damper servo sub-assembly*3 Min.: 128, Max.: 383 Operates between 254 to 360 pulses
      No. 3 air conditioning radiator damper servo sub-assembly (driver side lower)*4 Min.: 128, Max.: 383 Operates between 254 to 360 pulses
      Cool A/M Servo Pulse(P) No. 3 air conditioning radiator damper servo sub-assembly (front passenger side lower)*3 Min.: 128, Max.: 383 Operates between 254 to 360 pulses
      No. 4 air conditioning radiator damper servo sub-assembly*4 Min.: 128, Max.: 383 Operates between 254 to 360 pulses
      A/O Servo Pulse(Rr D) No. 7 air conditioning radiator damper servo sub-assembly Min.: 128, Max.: 383 Operates between 242 to 353 pulses
      Rear Air Mix Servo Targ Pulse*2 No. 3 air conditioning radiator damper servo sub-assembly (rear air mix) Min.: 128, Max.: 383 Operates between 254 to 360 pulses
      DEF A/O Servo Pulse(D) No. 1 air conditioning radiator damper servo sub-assembly Min.: 128, Max.: 383 Operates between 164 to 270 pulses
      Ion Generator*8 No. 1 ion generator sub-assembly OFF, ON -

      • *1: w/ PTC Heater

      • *2: w/ Rear Control Switch

      • *3: for LHD

      • *4: for RHD

      • *5: for LHD or RHD without Rear Control Switch

      • *6: for RHD with Rear Control Switch

      • *7: for LHD with Rear Control Switch

      • *8: w/ Ion Generator