INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY LH
| *1 | Motor Gear |
| *a | Component without harness connected (Power Window Regulator Motor Assembly LH) |
|
Clockwise |
|
Counterclockwise |
Note
Do not apply positive (+) battery voltage to any terminals, except terminal 2 (B), to avoid damaging the pulse sensor inside the motor.
Apply positive (+) battery voltage to the connector terminal 2 (B).
Apply negative (-) battery voltage to the connector terminals 1 (E) and 7 (DWN1) / 10 (UP1).
Check that the motor gear rotates smoothly as follows.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → 2 (B) Battery negative (-): 1 (E) (3 seconds or more) → 1 (E) and 10 (UP1) (within 1 second) → 1 (E) (within 1 second) → 1 (E) and 10 (UP1) |
Motor gear rotates clockwise (UP) |
| Battery positive (+) → 2 (B) Battery negative (-): 1 (E) (3 seconds or more) → 1 (E) and 7 (DWN1) (within 1 second) → 1 (E) (within 1 second) → 1 (E) and 7 (DWN1) |
Motor gear rotates counterclockwise (DOWN) |
If the result is not as specified, replace the power window regulator motor assembly LH.
CAUTION:
Reset the power window regulator motor (initialize the pulse sensor) after installing the power window regulator motor and regulator assembly onto the door.
INSPECT POWER WINDOW REGULATOR MOTOR ASSEMBLY RH
| *1 | Motor Gear |
| *a | Component without harness connected (Power Window Regulator Motor Assembly LH) |
|
Clockwise |
|
Counterclockwise |
Note
Do not apply positive (+) battery voltage to any terminals, except terminal 2 (B), to avoid damaging the pulse sensor inside the motor.
Apply positive (+) battery voltage to the connector terminal 2 (B).
Apply negative (-) battery voltage to the connector terminals 1 (E) and 7 (DWN1) / 10 (UP1).
Check that the motor gear rotates smoothly as follows.
| Measurement Condition | Specified Condition |
|---|---|
| Battery positive (+) → 2 (B) Battery negative (-): 1 (E) (3 seconds or more) → 1 (E) and 10 (UP1) (within 1 second) → 1 (E) (within 1 second) → 1 (E) and 10 (UP1) |
Motor gear rotates clockwise (UP) |
| Battery positive (+) → 2 (B) Battery negative (-): 1 (E) (3 seconds or more) → 1 (E) and 7 (DWN1) (within 1 second) → 1 (E) (within 1 second) → 1 (E) and 7 (DWN1) |
Motor gear rotates counterclockwise (DOWN) |
If the result is not as specified, replace the power window regulator motor assembly RH.
CAUTION:
Reset the power window regulator motor (initialize the pulse sensor) after installing the power window regulator motor and regulator assembly onto the door.