AUTOMATIC TRANSMISSION SYSTEM, Diagnostic DTC:P2716

DTC Code DTC Name
P2716 Pressure Control Solenoid "D" Electrical (Shift Solenoid Valve SLT)

DESCRIPTION

Refer to DTC P0894 Click here.

DTC No. DTC Detection Condition Trouble Area
P2716 Open or short is detected in shift solenoid valve SLT circuit for 1 second or more while driving (1-trip detection logic).
  • Open or short in shift solenoid valve SLT circuit

  • Shift solenoid valve SLT

  • ECM

MONITOR DESCRIPTION

When an open or short in the linear solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault. The ECM will turn on the MIL and store the DTC.

WIRING DIAGRAM

A01FG9QE07

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT TRANSMISSION WIRE (SLT)


    1. A01FEYSE59
      Text in Illustration
      *1

      Component without harness connected

      (Transmission Wire)

      Disconnect the transmission wire connector from the transmission.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection

      Specified Condition

      20°C (68°F)

      13 (SLT+) - 5 (SLT-) 5.0 to 5.6 Ω
    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for short)
      Tester Connection Specified Condition
      13 (SLT+) - Body ground 10 kΩ or higher
      5 (SLT-) - Body ground

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (TRANSMISSION WIRE - ECM)


    1. A01FG3YE03
      Text in Illustration
      *1

      Rear view of wire harness connector

      (to ECM)

      Connect the transmission wire connector to the transmission.

    2. Disconnect the ECM connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection

      Specified Condition

      20°C (68°F)

      F3-5 (SLT+) - F3-4 (SLT-) 5.0 to 5.6 Ω
    4. Measure the resistance according to the value(s) in the table below.

      Standard resistance (Check for short)
      Tester Connection Specified Condition
      F3-5 (SLT+) - Body ground 10 kΩ or higher
      F3-4 (SLT-) - Body ground

    NG
    OK
  3. INSPECT SHIFT SOLENOID VALVE SLT


    1. A01FDHVE10
      Text in Illustration
      *1 Shift Solenoid Valve SLT

      Remove the shift solenoid valve SLT.

    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance
      Tester Connection

      Specified Condition

      20°C (68°F)

      1 - 2 5.0 to 5.6 Ω
    3. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the solenoid valve connector, then check the movement of the valve.

      OK
      The solenoid makes an operating sound.

    NG
    OK