VALVE BODY ASSEMBLY INSPECTION


  1. INSPECT SHIFT SOLENOID VALVE SL1 AND SL2


    1. A01FI7WE08
      Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve SL1 and SL2)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Connect the positive (+) lead with a 21 W bulb to terminal 1 and the negative (-) lead to terminal 2 of the shift solenoid valve connector, then check the movement of the valve.

      OK
      The solenoid makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve.

  2. INSPECT SHIFT SOLENOID VALVE S1 AND S3


    1. A01FH2CE03
      Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve S1 and S3)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve connector terminal - Shift solenoid valve body 20°C (68°F) 11 to 15 Ω
    2. Connect the positive (+) lead to the terminal of the shift solenoid valve connector, and the negative (-) lead to the shift solenoid valve body..

      OK
      The solenoid makes an operating sound.

      If the result is not as specified, replace the shift solenoid valve.

  3. INSPECT SHIFT SOLENOID VALVE S2


    1. A01FIRFE02
      Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve S2)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve S2 connector terminal - Shift solenoid valve S2 body 20°C (68°F) 11 to 15 Ω
    2. Connect the positive (+) lead to the terminal of the shift solenoid valve S2 connector, and the negative (-) lead to the shift solenoid valve S2 body.

      OK
      The solenoid makes an operating sound.

      If the result is not as specified, replace shift solenoid valve S2.

  4. INSPECT SHIFT SOLENOID VALVE S4


    1. A01FF1UE03
      Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve S4)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve S4 connector terminal - Shift solenoid valve S4 body 20°C (68°F) 11 to 15 Ω
    2. Connect the positive (+) lead to the terminal of the shift solenoid valve S4 connector, and the negative (-) lead to the shift solenoid valve S4 body.

      OK
      The solenoid makes an operating sound.

      If the result is not as specified, replace shift solenoid valve S4.

  5. INSPECT SHIFT SOLENOID VALVE SR


    1. A01FHAKE02
      Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve SR)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Shift solenoid valve SR connector terminal - Shift solenoid valve SR body 20°C (68°F) 11 to 15 Ω
    2. Connect the positive (+) lead to the terminal of the shift solenoid valve SR connector, and the negative (-) lead to the shift solenoid valve SR body.

      OK
      The solenoid makes an operating sound.

      If the result is not as specified, replace shift solenoid valve SR.

  6. INSPECT SHIFT SOLENOID VALVE SLT


    1. A01FDHVE02
      Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve SLT)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the shift solenoid valve SLT connector, then check the movement of the valve.

      OK
      The solenoid makes an operating sound.

      If the result is not as specified, replace shift solenoid valve SLT.

  7. INSPECT SHIFT SOLENOID VALVE SLU


    1. A01FDHVE04
      Text in Illustration
      *a

      Component without harness connected

      (Shift Solenoid Valve SLU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 20°C (68°F) 5.0 to 5.6 Ω
    2. Connect the positive (+) lead with a 21 W bulb to terminal 2 and the negative (-) lead to terminal 1 of the shift solenoid valve SLU connector, then check the movement of the valve.

      OK
      The solenoid makes an operating sound.

      If the result is not as specified, replace shift solenoid valve SLU.