PARK ASSIST / MONITORING SERVICE DATA

ULTRASONIC SENSOR (for Front Side)
Connector Condition Tester Connection Condition Specified Condition
Component without harness connected 1 (BI) - 5 (EI) Always 10 kΩ or higher
1 (BI) - 2 (B0) Always 10 kΩ or higher
3 (S1) - 4 (SO) Always Below 1 Ω
5 (EI) - 6 (EO Always Below 1 Ω
ULTRASONIC SENSOR (for Rear Side)
Connector Condition Tester Connection Condition Specified Condition
Component without harness connected 1 (BI) - 5 (EI) Always 10 kΩ or higher
1 (BI) - 2 (B0) Always 10 kΩ or higher
3 (S1) - 4 (SO) Always Below 1 Ω
5 (EI) - 6 (EO Always Below 1 Ω
CLEARANCE SONAR MAIN SWITCH
Connector Condition Tester Connection Switch Condition Specified Condition
Component without harness connected 4(IG) - 5 (ECU) Back sonar or clearance sonar switch assembly on Below 1 Ω
4(IG) - 5 (ECU) Back sonar or clearance sonar switch assembly off 10 kΩ or higher
BLIND SPOT MONITOR MAIN SWITCH
Connector Condition Tester Connection Switch Condition Specified Condition
Component without harness connected 1 (B) - 16 (B) Blind spot monitor main switch (integration control and panel assembly) on Below 1 Ω
1 (B) - 16 (B) Blind spot monitor main switch (integration control and panel assembly) off 10 kΩ or higher